Literature DB >> 7690875

Automated detection of cytochalasin-B blocked binucleated lymphocytes for scoring micronuclei.

P Castelain1, P Van Hummelen, A Deleener, M Kirsch-Volders.   

Abstract

A comparison between manual and computer-based automatic scoring of micronuclei (MN) was performed in order to optimize the preparation technique and to validate the image analysis procedure. For this purpose whole human blood of three donors was either irradiated (1 Gy X-rays) or treated with the chemical mutagen methyl methane sulphonate (25 mg/ml) and cultivated in the presence of cytochalasin B to obtain binucleated cells with a high yield of MN. An algorithm for MN detection has been developed for Giemsa (G)- and Feulgen-Congo-Red (FCR)-stained slides. This algorithm contains a sequence of grey operators and binary operators necessary to detect nuclei and MN, and to efficiently reject artefacts. The output is a data file with measurements of cells and intracellular inclusions. From these features, information can be extracted concerning the frequency of the various cell classes (based on nuclearity), the presence of MN and various shape parameters. A close analysis of the automatic scoring of G- and FCR-stained cells, revealed that 59-86% of all automatically classified binucleated cytokinesis-blocked (CB) cells were correctly classified. Although some MN were overlooked during automated scoring, the results show that, on average, similar MN frequencies are obtained with automated and manual scoring. The errors which occurred were mainly due to the misclassification of CB cells, the non-detection of extremely small MN and the aggregation of MN to the main nucleus. The possibility of scanning high numbers of cells overnight, to relocate CB cells with potential MN and the quantitative character of the results offers good prospects for future use in the in vitro MN test.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 7690875     DOI: 10.1093/mutage/8.4.285

Source DB:  PubMed          Journal:  Mutagenesis        ISSN: 0267-8357            Impact factor:   3.000


  7 in total

Review 1.  Laser scanning cytometry for automation of the micronucleus assay.

Authors:  Zbigniew Darzynkiewicz; Piotr Smolewski; Elena Holden; Ed Luther; Mel Henriksen; Maxime François; Wayne Leifert; Michael Fenech
Journal:  Mutagenesis       Date:  2011-01       Impact factor: 3.000

Review 2.  Radiation signature on exposed cells: Relevance in dose estimation.

Authors:  Venkatachalam Perumal; Tamizh Selvan Gnana Sekaran; Venkateswarlu Raavi; Safa Abdul Syed Basheerudeen; Karthik Kanagaraj; Amith Roy Chowdhury; Solomon Fd Paul
Journal:  World J Radiol       Date:  2015-09-28

3.  Automated analysis of the cytokinesis-block micronucleus assay for radiation biodosimetry using imaging flow cytometry.

Authors:  M A Rodrigues; L A Beaton-Green; B C Kutzner; R C Wilkins
Journal:  Radiat Environ Biophys       Date:  2014-03-07       Impact factor: 1.925

4.  Fast image analysis for the micronucleus assay in a fully automated high-throughput biodosimetry system.

Authors:  Oleksandra V Lyulko; Guy Garty; Gerhard Randers-Pehrson; Helen C Turner; Barbara Szolc; David J Brenner
Journal:  Radiat Res       Date:  2014-02-06       Impact factor: 2.841

5.  Assessment of the micronucleus assay as a biological dosimeter using cytokinesis-blocked lymphocytes from cancer patients receiving fractionated partial body-radiotherapy.

Authors:  J le Roux; J Slabbert; B Smit; G Blekkenhorst
Journal:  Strahlenther Onkol       Date:  1998-02       Impact factor: 3.621

6.  Seven benzimidazole pesticides combined at sub-threshold levels induce micronuclei in vitro.

Authors:  Sibylle Ermler; Martin Scholze; Andreas Kortenkamp
Journal:  Mutagenesis       Date:  2013-04-01       Impact factor: 3.000

Review 7.  Estimation of the effects of medical diagnostic radiation exposure based on DNA damage.

Authors:  Lin Shi; Satoshi Tashiro
Journal:  J Radiat Res       Date:  2018-04-01       Impact factor: 2.724

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.