Literature DB >> 7681562

Initial experience with transvenous implantable cardioverter defibrillator lead systems: operative morbidity and mortality.

R Frame1, R Brodman, J Gross, I Hollinger, J D Fisher, S G Kim, K Ferrick, J Roth, U Ben-Zur, S Furman.   

Abstract

Introduction of non-thoracotomy lead systems (Medtronic, Inc.) for the implantable cardioverter defibrillator (ICD) has expanded the indications for use of this mode of therapy. Patients previously considered "too ill" to undergo a thoracotomy as well as patients who are at a high risk for developing sudden death but without previous cardiac arrest, are now considered candidates. The initial experience with the non-thoracotomy lead system at our institution was analyzed for morbidity and mortality. Thirty-four patients underwent attempted intravascular lead implantation, with 30 having initial successful implantation (88.2%). There were 23 males; average ejection fraction (EF) was 38.6%. Three patients developed pulmonary edema and low output immediately after the procedure. Three patients developed electromechanical dissociation during defibrillation threshold testing. A prolonged testing time for the non-thoracotomy lead system was noted when compared to the thoracotomy system (57.39 vs 32.30 min; P < 0.0000). There were more intraoperative morbidities with the non-thoracotomy leads than with the thoracotomy system. There were no perioperative deaths. The potential consequences of prolonged anesthesia time and extensive defibrillation threshold testing should be considered when choosing the route of ICD implant, the type of anesthesia, and the intraoperative testing protocol for each patient.

Entities:  

Mesh:

Year:  1993        PMID: 7681562     DOI: 10.1111/j.1540-8159.1993.tb01552.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

Review 1.  [Cardiology update. I: Electrophysiology].

Authors:  P Weismüller; H J Trappe
Journal:  Med Klin (Munich)       Date:  1999-01-15

2.  Clinical experience with the transvenous Medtronic Pacer Cardioverter Defibrillator (PCD) System.

Authors:  A Golino; C Pappone; A Panza; M Santomauro; D Iorio; V De Amicis; M Chiariello; N Spampinato
Journal:  Tex Heart Inst J       Date:  1993

3.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.

Authors:  Bruce L Wilkoff; Laurent Fauchier; Martin K Stiles; Carlos A Morillo; Sana M Al-Khatib; Jesœs Almendral; Luis Aguinaga; Ronald D Berger; Alejandro Cuesta; James P Daubert; Sergio Dubner; Kenneth A Ellenbogen; N A Mark Estes; Guilherme Fenelon; Fermin C Garcia; Maurizio Gasparini; David E Haines; Jeff S Healey; Jodie L Hurtwitz; Roberto Keegan; Christof Kolb; Karl-Heinz Kuck; Germanas Marinskis; Martino Martinelli; Mark McGuire; Luis G Molina; Ken Okumura; Alessandro Proclemer; Andrea M Russo; Jagmeet P Singh; Charles D Swerdlow; Wee Siong Teo; William Uribe; Sami Viskin; Chun-Chieh Wang; Shu Zhang
Journal:  J Arrhythm       Date:  2016-02-01
  3 in total