Literature DB >> 7677488

Application of a new tactile sensor to thoracoscopic surgery: experimental and clinical study.

T Ohtsuka1, A Furuse, T Kohno, J Nakajima, K Yagyu, S Omata.   

Abstract

BACKGROUND: We developed a new tactile sensor that could quantify the hardness of objects as changes in the resonance frequency of the sensor (delta f). We have applied it to thoracoscopic operations for the localization of small invisible nodules in the lung.
METHODS: When the sensor probe was moved over the lung surface, a delta f curve was depicted on the computer screen. When the sensor tip reached a point directly above a hard object, a sudden upward jump of the delta f curve was evoked. After experimental studies using pigs, the sensor was applied in 8 patients. More recently we produced a needle sensor to distinguish small nodules from bronchi that may evoke similar upward jumps of the delta f curve. Eight nodules and four bronchi in resected human lungs were probed directly using this sensor.
RESULTS: In all of the patients, the hardness of various thoracic structures could be quantified. A total of 10 nodules were found using the sensor and resected thoracoscopically. The needle sensor distinguished nodules from bronchi, as the mean delta f of the bronchial walls (-64 +/- 45.9 Hz) was significantly higher than that of nodules (-526 +/- 168 Hz, p < 0.001).
CONCLUSIONS: Thoracoscopic detection of small and invisible pulmonary nodules using our new tactile sensor is feasible.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7677488     DOI: 10.1016/0003-4975(95)00483-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

Review 1.  Pulmonary metastasis: rationale for local treatments and techniques.

Authors:  Jun Nakajima
Journal:  Gen Thorac Cardiovasc Surg       Date:  2010-09-22

2.  Thoracoscopic surgery and conventional open thoracotomy in metastatic lung cancer.

Authors:  J Nakajima; S Takamoto; M Tanaka; E Takeuchi; T Murakawa; T Fukami
Journal:  Surg Endosc       Date:  2001-05-07       Impact factor: 4.584

Review 3.  Intrathoracoscopic localization techniques. Review of literature.

Authors:  D Sortini; C Feo; K Maravegias; P Carcoforo; E Pozza; A Liboni; A Sortini
Journal:  Surg Endosc       Date:  2006-05-13       Impact factor: 4.584

4.  A new Tissue Resonator Indenter Device and reliability study.

Authors:  Ming Jia; Jean W Zu; Alireza Hariri
Journal:  Sensors (Basel)       Date:  2011-01-20       Impact factor: 3.576

Review 5.  Recent Progress in Technologies for Tactile Sensors.

Authors:  Cheng Chi; Xuguang Sun; Ning Xue; Tong Li; Chang Liu
Journal:  Sensors (Basel)       Date:  2018-03-22       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.