Literature DB >> 7673758

Improving the applicability of myocardial densitometry and parametric imaging by extended automated densogram analysis.

M Lang1, R Brennecke, M Haude, U Renneisen, R Erbel, J Meyer.   

Abstract

In clinical applications the analysis of X-ray contrast densograms acquired in regions of interest (ROI's) over the myocardium is disturbed by many complex factors. For this reason we acquire redundant densogram information for quality control before extracting densitometric parameters. In our approach, initially some stable measures of quality for densograms are used to lower the influence of poor quality densograms by a quality weighted averaging. For example a shape quality measure, Q1, is calculated using regions of optimal and minimal acceptable quality defined with respect to a prototype densogram. Not a few myocardial ROI's yield densograms that differ from single-source densograms (SSD's) due to e.g. superposition of different perfusion beds or the position of the ROI relative to the coronary sinus or stenoses. This might result in a densogram shape with oscillating or plateau behavior. For densograms of a such general shape many parameters defined in the usual way do not depend smoothly on the densogram values. The conventional definitions of some parameters (appearance time, rise time) are therefore extended for application to multi-maxima densograms as well as to SSD's. These new methods are evaluated using digitized clinical angiocardiograms and are applied to parametric imaging (pixeldensograms) in a slightly modified way. Taking into account the densogram quality, its shape and its origin results in a considerable improvement both for densitometry and parametric imaging of myocardial perfusion.

Entities:  

Mesh:

Year:  1995        PMID: 7673758     DOI: 10.1007/bf01844708

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  9 in total

1.  Mean transit time for videodensitometric assessment of myocardial perfusion and the concept of maximal flow ratio: a validation study in the intact dog and a pilot study in man.

Authors:  N H Pijls; G J Uijen; A Hoevelaken; T Pijnenburg; K L van Leeuwen; J H Fast; H S Bos; W R Aengevaeren; T van der Werf
Journal:  Int J Card Imaging       Date:  1990

2.  INDICATOR TRANSIT TIME CONSIDERED AS A GAMMA VARIATE.

Authors:  H K THOMPSON; C F STARMER; R E WHALEN; H D MCINTOSH
Journal:  Circ Res       Date:  1964-06       Impact factor: 17.367

3.  Comparison of three different principles in the assessment of coronary flow reserve from digital angiograms.

Authors:  R Simon; G Herrmann; I Amende
Journal:  Int J Card Imaging       Date:  1990

4.  Parametric assessment of myocardial perfusion during interventional cardiac catheterization by means of X-ray densitometry-short-and long-term results.

Authors:  M Haude; R Brennecke; R Erbel; M Lang; H P Deutsch; U Renneisen; J Meyer
Journal:  Int J Card Imaging       Date:  1990

5.  Determination of coronary flow reserve by digital angiography: validation of a practical method not requiring power injection or electrocardiographic gating.

Authors:  J C Gurley; S E Nissen; J L Elion; D C Booth; A N DeMaria
Journal:  J Am Coll Cardiol       Date:  1990-07       Impact factor: 24.094

6.  Digital angiographic measurement of radiographic contrast material kinetics for estimation of myocardial perfusion.

Authors:  J S Whiting; J K Drury; J M Pfaff; B L Chang; N L Eigler; S Meerbaum; E Corday; T Nivatpumin; J S Forrester; H J Swan
Journal:  Circulation       Date:  1986-04       Impact factor: 29.690

7.  Time and flow parameter extraction in digital angiography: principles and methods.

Authors:  H J Hahne
Journal:  Herz       Date:  1985-08       Impact factor: 1.443

8.  The concept of apparent cardiac arrest as a prerequisite for coronary digital subtraction angiography.

Authors:  T van der Werf; R M Heethaar; H Stegehuis; F L Meijler
Journal:  J Am Coll Cardiol       Date:  1984-08       Impact factor: 24.094

9.  Application of digital techniques to selective coronary arteriography: use of myocardial contrast appearance time to measure coronary flow reserve.

Authors:  R Vogel; M LeFree; E Bates; W O'Neill; R Foster; P Kirlin; D Smith; B Pitt
Journal:  Am Heart J       Date:  1984-01       Impact factor: 4.749

  9 in total
  2 in total

1.  3D assessment of myocardial perfusion parameter combined with 3D reconstructed coronary artery tree from digital coronary angiograms.

Authors:  T H Schindler; N Magosaki; M Jeserich; E Nitzsche; U Oser; T Abdollahnia; M Nageleisen; M Zehender; H Just; U Solzbach
Journal:  Int J Card Imaging       Date:  2000-02

Review 2.  [New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].

Authors:  M Haude; G Caspari; D Baumgart; P Spiller; G Heusch; R Erbel
Journal:  Herz       Date:  1997-04       Impact factor: 1.443

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.