Literature DB >> 7671366

The etiology of syncope in patients with negative tilt table and electrophysiological testing.

A D Krahn1, G J Klein, C Norris, R Yee.   

Abstract

BACKGROUND: Patients with syncope of unknown etiology after negative noninvasive and electrophysiological testing may suffer from recurrent disability. Syncopal episodes are often too infrequent and unpredictable for detection by conventional ambulatory monitoring techniques. METHODS AND
RESULTS: A long-term subcutaneous monitoring device was implanted in patients with negative ambulatory monitoring, tilt table and electrophysiological testing to establish cardiac rhythm during spontaneous syncope. Sixteen patients aged 57 +/- 19 years with a mean of 8.4 +/- 4.4 previous episodes of syncope underwent device implantation. Fifteen patients (94%) had recurrent syncope 4.4 +/- 4.2 months after implantation. The remaining patient has not had recurrent syncope and continues to be followed. A diagnosis was obtained in every patient who had recurrent episode. Syncope was secondary to sinus arrest in 5, atrioventricular block in 2, ventricular tachycardia in 1, supraventricular tachycardia in 1, and nonarrhythmic in 6. Successful therapy was implemented in all 15 patients, without recurrence of syncope during 13.0 +/- 8.4 months of follow-up.
CONCLUSIONS: Unexplained syncope in patients with negative investigations has a broad spectrum of etiologies, the most common of which is bradycardia. An implantable long-term monitoring device is useful for establishing a diagnosis when symptoms are recurrent but too infrequent for conventional monitoring techniques.

Entities:  

Mesh:

Year:  1995        PMID: 7671366     DOI: 10.1161/01.cir.92.7.1819

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  27 in total

Review 1.  Current investigations used to assess syncope.

Authors:  W Arthur; G C Kaye
Journal:  Postgrad Med J       Date:  2001-01       Impact factor: 2.401

2.  Implantable loop recorder: evaluation of unexplained syncope.

Authors:  R A Kenny; A D Krahn
Journal:  Heart       Date:  1999-04       Impact factor: 5.994

3.  Recording that elusive rhythm.

Authors:  A D Krahn; G J Klein; R Yee; A C Skanes
Journal:  CMAJ       Date:  1999-11-30       Impact factor: 8.262

Review 4.  Evaluation of syncope.

Authors:  M Yousuf Kanjwal; Blair P Grubb
Journal:  Curr Cardiol Rep       Date:  2005-09       Impact factor: 2.931

Review 5.  How to avoid a misdiagnosis in patients presenting with transient loss of consciousness.

Authors:  Sanjiv Petkar; Paul Cooper; Adam P Fitzpatrick
Journal:  Postgrad Med J       Date:  2006-10       Impact factor: 2.401

6.  Guidelines for the diagnosis and management of syncope (version 2009).

Authors:  Angel Moya; Richard Sutton; Fabrizio Ammirati; Jean-Jacques Blanc; Michele Brignole; Johannes B Dahm; Jean-Claude Deharo; Jacek Gajek; Knut Gjesdal; Andrew Krahn; Martial Massin; Mauro Pepi; Thomas Pezawas; Ricardo Ruiz Granell; Francois Sarasin; Andrea Ungar; J Gert van Dijk; Edmond P Walma; Wouter Wieling
Journal:  Eur Heart J       Date:  2009-08-27       Impact factor: 29.983

7.  2015 heart rhythm society expert consensus statement on the diagnosis and treatment of postural tachycardia syndrome, inappropriate sinus tachycardia, and vasovagal syncope.

Authors:  Robert S Sheldon; Blair P Grubb; Brian Olshansky; Win-Kuang Shen; Hugh Calkins; Michele Brignole; Satish R Raj; Andrew D Krahn; Carlos A Morillo; Julian M Stewart; Richard Sutton; Paola Sandroni; Karen J Friday; Denise Tessariol Hachul; Mitchell I Cohen; Dennis H Lau; Kenneth A Mayuga; Jeffrey P Moak; Roopinder K Sandhu; Khalil Kanjwal
Journal:  Heart Rhythm       Date:  2015-05-14       Impact factor: 6.343

8.  [Significance of diagnostic methods in the work-up of syncope].

Authors:  C Strotmann; N Rüb; C Wolpert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-06

9.  The diagnostic yield of implantable loop recorders stratified by indication: "real-world" use in a large academic hospital.

Authors:  Alexander Smith; Makenzie Perdue; Jetmir Vojnika; Daniel R Frisch; Behzad B Pavri
Journal:  J Interv Card Electrophysiol       Date:  2020-07-04       Impact factor: 1.900

Review 10.  Implantable diagnostic monitoring devices for evaluation of syncope, and tachy- and brady-arrhythmias.

Authors:  David G Benditt; Cengiz Ermis; Scott Pham; Laura Hiltner; Amy Vrudney; Keith G Lurie; Scott Sakaguchi
Journal:  J Interv Card Electrophysiol       Date:  2003-10       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.