Literature DB >> 7670216

Primary treatment of unstable Jefferson's fractures.

R A McGuire1, H L Harkey.   

Abstract

The Magerl transfacet screw technique is a method of fixation for unstable burst fractures of the atlas (Jefferson's fracture) that precludes the use of a halo brace or stabilization from the occiput to C2. Two cases are presented utilizing this mode of treatment to obtain solid arthrodesis and maintain intact motion at occipital cervical junction. No increased displacement of the fractured ring of C1 occurred with the screw insertion. Thus, primary C1-C2 transfacet screw fixation is a useful alternative treatment for unstable Jefferson's fractures.

Entities:  

Mesh:

Year:  1995        PMID: 7670216     DOI: 10.1097/00002517-199506000-00010

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  6 in total

1.  Posterior Fusion in Patients with Trauma, Instability, and Tumor of the Cervical Spine.

Authors:  Dr Hans-Joachim Riesner; Sebastian Katscher; Thomas Blattert; Christoph Josten
Journal:  Eur J Trauma Emerg Surg       Date:  2009-05-07       Impact factor: 3.693

2.  A biomechanical rationale for C1-ring osteosynthesis as treatment for displaced Jefferson burst fractures with incompetency of the transverse atlantal ligament.

Authors:  Heiko Koller; Herbert Resch; Mark Tauber; Juliane Zenner; Peter Augat; Rainer Penzkofer; Frank Acosta; Klaus Kolb; Anton Kathrein; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2010-04-13       Impact factor: 3.134

3.  Unstable atlas fracture treatment by anterior plate C1-ring osteosynthesis using a transoral approach.

Authors:  Weihu Ma; Nanjian Xu; Yong Hu; Guoqing Li; Liujun Zhao; Shaohua Sun; Weiyu Jiang; Guanyi Liu; Yongjie Gu; Jiayong Liu
Journal:  Eur Spine J       Date:  2013-06-18       Impact factor: 3.134

4.  Case report: nonoperative treatment of an unstable Jefferson fracture using a cervical collar.

Authors:  Brian M Haus; Mitchel B Harris
Journal:  Clin Orthop Relat Res       Date:  2008-02-08       Impact factor: 4.176

5.  Direct Fixation of C1 Jefferson Fracture Using C1 Lateral Mass Screws: A Case Report.

Authors:  Aravind Kumar; James Onggo; Lim Hai Fon; Jacob Oh
Journal:  Int J Spine Surg       Date:  2019-08-31

6.  Comparison of occipitocervical and atlantoaxial fusion in treatment of unstable Jefferson fractures.

Authors:  Yong Hu; Zhen-Shan Yuan; Christopher K Kepler; Wei-Xin Dong; Xiao-Yang Sun; Jiao Zhang
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

  6 in total