Literature DB >> 7668462

Technetium-99m-sestamibi single agent localization versus high resolution ultrasonography for the preoperative localization of parathyroid glands in patients with primary hyperparathyroidism.

H T Billy1, D R Rimkus, S Hartzman, R G Latimer.   

Abstract

Technetium 99m sestamibi, a newer radionuclide agent, has shown promise in parathyroid scintigraphy. Recent studies using technetium 99m sestamibi in conjunction with subtraction iodine I123 imaging have demonstrated accuracy for localizing parathyroid glands in patients with hyperparathyroidism. The effectiveness of technetium 99m sestamibi scanning as a single agent was compared prospectively with conventional high resolution ultrasonography for the preoperative localization of abnormal parathyroid glands in patients with primary hyperparathyroidism. Seventeen patients with primary hyperparathyroidism had preoperative evaluation with high resolution ultrasonography and technetium 99m sestamibi radionuclide scanning. All patients underwent bilateral neck exploration. Ultrasound results were made available to the surgeon preoperatively; however, technetium 99m sestamibi results were withheld unless specifically asked for by the surgeon intraoperatively. Comparison of the imaging studies were correlated with the operative and histological findings. Of 17 patients, 12 had solitary adenomas and four had diffuse hyperplasia. In one patient no abnormal glands were discovered. In patients with technetium 99m sestamibi localization, a solitary adenoma was identified correctly in 10 of 12 patients (83%). Three of four patients with diffuse hyperplasia had parathyroid sestamibi scans showing nonfocal or diffuse uptake in multiple glands. High resolution ultrasonography correctly identified only six of 12 patients with solitary parathyroid adenomas (50%). Of the patients with diffuse hyperplasia, two ultrasound studies showed a single enlarged gland, one study was negative, and one localized two questionable, enlarged glands. Technetium 99m sestamibi is effective as a single agent for preoperative parathyroid scintigraphy.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7668462

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  4 in total

1.  Accuracy of surgeon-performed ultrasound in parathyroid localization.

Authors:  Russell Van Husen; Lawrence T Kim
Journal:  World J Surg       Date:  2004-11       Impact factor: 3.352

2.  Role of Virtual Biopsy in the Management of Renal Masses.

Authors:  Alberto Diaz de Leon; Matthew S Davenport; Stuart G Silverman; Nicola Schieda; Jeffrey A Cadeddu; Ivan Pedrosa
Journal:  AJR Am J Roentgenol       Date:  2019-04-17       Impact factor: 3.959

Review 3.  Clinical value of parathyroid scintigraphy with technetium-99m methoxyisobutylisonitrile: discrepancies in clinical data and a systematic metaanalysis of the literature.

Authors:  Martin Gotthardt; Bodo Lohmann; Thomas M Behr; Artur Bauhofer; Christiane Franzius; Meike L Schipper; Maria Wagner; Helmut Höffken; Helmut Sitter; Matthias Rothmund; Klaus Joseph; Christoph Nies
Journal:  World J Surg       Date:  2003-11-26       Impact factor: 3.352

4.  Preoperative ultrasound and nuclear medicine studies improve the accuracy in localization of adenoma in hyperparathyroidism.

Authors:  Bryan A Whitson; Thomas A Broadie
Journal:  Surg Today       Date:  2008-02-29       Impact factor: 2.549