Literature DB >> 7667933

Motion perception deficits in glaucomatous optic neuropathy.

G L Trick1, S B Steinman, M Amyot.   

Abstract

The mechanisms mediating impaired motion perception in glaucoma were investigated. Direction discrimination thresholds for low (4.2 deg/sec) and high (12.5 deg/sec) velocity random-dot kinematograms were measured in controls and patients with glaucoma or ocular hypertension. Thresholds were elevated significantly in glaucoma patients and individual ocular hypertensives. Threshold elevations were not due to blur or pupil size. After compensating for motion reversals, high but not low velocity thresholds remained elevated. Only high velocity thresholds correlated with differential luminance sensitivity. A hypothesis that different mechanisms mediate glaucoma-induced deficits at high and low velocities is presented.

Entities:  

Mesh:

Year:  1995        PMID: 7667933     DOI: 10.1016/0042-6989(94)00311-4

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  5 in total

1.  Global motion perception is independent from contrast sensitivity for coherent motion direction discrimination and visual acuity in 4.5-year-old children.

Authors:  Arijit Chakraborty; Nicola S Anstice; Robert J Jacobs; Nabin Paudel; Linda L LaGasse; Barry M Lester; Trecia A Wouldes; Jane E Harding; Benjamin Thompson
Journal:  Vision Res       Date:  2015-09-02       Impact factor: 1.886

2.  Temporal contrast sensitivity with peripheral and central stimulation in glaucoma diagnosis.

Authors:  I M Velten; M Korth; F K Horn; W M Budde
Journal:  Br J Ophthalmol       Date:  1999-02       Impact factor: 4.638

3.  Structure-function relations of parasol cells in the normal and glaucomatous primate retina.

Authors:  Arthur J Weber; Christine D Harman
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-09       Impact factor: 4.799

4.  Global motion perception in 2-year-old children: a method for psychophysical assessment and relationships with clinical measures of visual function.

Authors:  Tzu-Ying Yu; Robert J Jacobs; Nicola S Anstice; Nabin Paudel; Jane E Harding; Benjamin Thompson
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-12-30       Impact factor: 4.799

5.  [Sensitivity and specificity of flicker perimetry with Pulsar. Comparison with achromatic (white-on-white) perimetry in glaucoma patients].

Authors:  K Göbel; C Erb
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.