Literature DB >> 7666698

Wavelets as alternative to short-time Fourier transform in signal-averaged electrocardiography.

B Gramatikov1, I Georgiev.   

Abstract

The paper reports experience of using the wavelet transform to build time-frequency distributions of the terminal portion of the QRS-complex. We used wavelets of Morlet at 12 scales, grouped in three sets, to analyse the frequency range 33-404 Hz. On the same patient data we applied the short-time Fourier transform and compared the results. Both representations reflected the time-frequency contents and detected irregular structures in the terminal portion of the QRS complex. The wavelet transform revealed more adequately QRS prolongations characteristic of patients prone to ventricular tachycardia. We may conclude that the wavelet transform can be a flexible alternative to short-time Fourier transform.

Entities:  

Mesh:

Year:  1995        PMID: 7666698     DOI: 10.1007/bf02510534

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  13 in total

1.  Standards for analysis of ventricular late potentials using high-resolution or signal-averaged electrocardiography: a statement by a task force committee of the European Society of Cardiology, the American Heart Association, and the American College of Cardiology.

Authors:  G Breithardt; M E Cain; N el-Sherif; N C Flowers; V Hombach; M Janse; M B Simson; G Steinbeck
Journal:  J Am Coll Cardiol       Date:  1991-04       Impact factor: 24.094

2.  Spectral and temporal interrogation of signal-averaged electrocardiograms: the best is yet to come.

Authors:  M E Cain; H D Ambos; B D Lindsay; J Markham; R M Arthur
Journal:  J Am Coll Cardiol       Date:  1989-12       Impact factor: 24.094

3.  A comparative study of frequency domain and time domain analysis of signal-averaged electrocardiograms in patients with ventricular tachycardia.

Authors:  J Machac; A Weiss; S L Winters; P Barecca; J A Gomes
Journal:  J Am Coll Cardiol       Date:  1988-02       Impact factor: 24.094

4.  Spectrotemporal analysis of ventricular late potentials.

Authors:  P Lander; D E Albert; E J Berbari
Journal:  J Electrocardiol       Date:  1990-04       Impact factor: 1.438

Review 5.  Comparison of time domain and frequency domain variables from the signal-averaged electrocardiogram: a multivariable analysis.

Authors:  S J Worley; D B Mark; W M Smith; P Wolf; R M Califf; H C Strauss; M G Manwaring; R E Ideker
Journal:  J Am Coll Cardiol       Date:  1988-05       Impact factor: 24.094

6.  Digital filters for the detection of late potentials in high-resolution ECG.

Authors:  B I Gramatikov
Journal:  Med Biol Eng Comput       Date:  1993-07       Impact factor: 2.602

7.  Detection of late potentials in the signal-averaged ECG combining time and frequency domain analysis.

Authors:  B I Gramatikov
Journal:  Med Biol Eng Comput       Date:  1993-07       Impact factor: 2.602

8.  Fast-Fourier transform analysis of signal-averaged electrocardiograms for identification of patients prone to sustained ventricular tachycardia.

Authors:  M E Cain; H D Ambos; F X Witkowski; B E Sobel
Journal:  Circulation       Date:  1984-04       Impact factor: 29.690

9.  Quantification of differences in frequency content of signal-averaged electrocardiograms in patients with compared to those without sustained ventricular tachycardia.

Authors:  M E Cain; H D Ambos; J Markham; A E Fischer; B E Sobel
Journal:  Am J Cardiol       Date:  1985-06-01       Impact factor: 2.778

10.  Signal-averaged electrocardiography in the time and frequency domains.

Authors:  T A Buckingham; C M Thessen; D Hertweck; D L Janosik; H L Kennedy
Journal:  Am J Cardiol       Date:  1989-04-01       Impact factor: 2.778

View more
  5 in total

1.  Analysis of myocardial infarction using discrete wavelet transform.

Authors:  E S Jayachandran; Paul Joseph K; R Acharya U
Journal:  J Med Syst       Date:  2009-05-20       Impact factor: 4.460

2.  Risk evaluation of ventricular tachycardia using wavelet transform irregularity of the high-resolution electrocardiogram.

Authors:  P Lewandowski; O Meste; R Maniewski; T Mroczka; K Steinbach; H Rix
Journal:  Med Biol Eng Comput       Date:  2000-11       Impact factor: 2.602

3.  Wavelet and pain rating index for inhalation anesthesia: A randomized controlled trial.

Authors:  Jian-Wen Zhang; Zhi-Gan Lv; Ying Kong; Chong-Fang Han; Bao-Guo Wang
Journal:  World J Clin Cases       Date:  2020-11-06       Impact factor: 1.337

4.  An Efficient and Automatic ECG Arrhythmia Diagnosis System using DWT and HOS Features and Entropy- Based Feature Selection Procedure.

Authors:  Abdullah Jafari Chashmi; Mehdi Chehel Amirani
Journal:  J Electr Bioimpedance       Date:  2019-08-20

5.  Detecting fixation on a target using time-frequency distributions of a retinal birefringence scanning signal.

Authors:  Boris Gramatikov
Journal:  Biomed Eng Online       Date:  2013-05-13       Impact factor: 2.819