Literature DB >> 7664993

Bond strength and microleakage of current dentin adhesives.

D Fortin1, E J Swift, G E Denehy, J W Reinhardt.   

Abstract

OBJECTIVES: The purpose of this in vitro study was to evaluate shear bond strengths and microleakage of seven current-generation dentin adhesive systems.
METHODS: Standard box-type Class V cavity preparations were made at the cemento-enamel junction on the buccal surfaces of eighty extracted human molars. These preparations were restored using a microfill composite following application of either All-Bond 2 (Bisco), Clearfil Liner Bond (Kuraray), Gluma 2000 (Miles), Imperva Bond (Shofu), OptiBond (Kerr), Prisma Universal Bond 3 (Caulk), Scotchbond Multi-Purpose (3M), or Scotchbond Dual-Cure (3M) (control). Lingual dentin of these same teeth was exposed and polished to 600-grit. Adhesives were applied and composite was bonded to the dentin using a gelatin capsule technique. Specimens were thermocycled 500 times. Shear bond strengths were determined using a universal testing machine, and microleakage was evaluated using a standard silver nitrate staining technique.
RESULTS: Clearfill Liner Bond and OptiBond, adhesive systems that include low-viscosity, low-modulus intermediate resins, had the highest shear bond strengths (13.3 +/- 2.3 MPa and 12.9 +/- 1.5 MPa, respectively). Along with Prisma Universal Bond 3, they also had the least microleakage at dentin margins of Class V restorations. SIGNIFICANCE: No statistically significant correlation between shear bond strength and microleakage was observed in this study. Adhesive systems that include a low-viscosity intermediate resin produced the high bond strengths and low microleakage. Similarly, two materials with bond strengths in the intermediate range had significantly increased microleakage, and one material with a bond strength in the low end of the spectrum exhibited microleakage that was statistically greater. Thus, despite the lack of statistical correlation, there were observable trends.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7664993     DOI: 10.1016/0109-5641(94)90070-1

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  12 in total

1.  Microleakage in class V gingiva-shaded composite resin restorations.

Authors:  Claudio Poggio; Marco Chiesa; Alberto Dagna; Marco Colombo; Andrea Scribante
Journal:  Ann Stomatol (Roma)       Date:  2012-05-03

2.  Effect of Diode Laser (810 nm) Irradiation on Marginal Microleakage of Multi-mode Adhesive Resins in Class V Composite Restorations.

Authors:  Niusha Golbari; Shahin Kasraei; Anahit Afrasiabi; Elahe Mostajir; Seyed Masoud Mojahedi
Journal:  J Lasers Med Sci       Date:  2019-10-01

3.  The influence of different composite placement techniques on microleakage in preparations with high C- factor: An in vitro study.

Authors:  Lekha Santhosh; Kusum Bashetty; Gururaj Nadig
Journal:  J Conserv Dent       Date:  2008-07

4.  Tertiary Amine and Tooth Mineral Hydroxyapatite Facilely Trigger Self-cure of 10-MDP Based Adhesives.

Authors:  Hang Liu; Yong Wang
Journal:  Int J Adhes Adhes       Date:  2019-05-15       Impact factor: 3.189

5.  Micro-tensile bond strength of adhesives to pulp chamber dentin after irrigation with Ethylenediaminetetraacetic acid.

Authors:  C Barutcigil; H Arslan; E Ozcan; Ot Harorlı
Journal:  J Conserv Dent       Date:  2012-07

6.  Effect of resin coating and chlorhexidine on microleakage of two resin cements after storage.

Authors:  F Shafie; M Doozandeh; A Alavi
Journal:  J Dent (Tehran)       Date:  2010-03-31

7.  Relationship between Operator Skill and In Vitro Microleakage of Different Adhesive Systems in Class V Restorations.

Authors:  Audrey Guéders; Sabine Geerts
Journal:  ISRN Dent       Date:  2010-11-29

8.  An in vitro evaluation of leakage of two etch and rinse and two self-etch adhesives after thermocycling.

Authors:  Sabine Geerts; Amandine Bolette; Laurence Seidel; Audrey Guéders
Journal:  Int J Dent       Date:  2012-05-22

9.  Enhancement performance of application mussel-biomimetic adhesive primer for dentin adhesives.

Authors:  Jiahui Zhang; Ying Zhao; Zilu Tian; Jiufu Zhu; Zuosen Shi; Zhanchen Cui; Song Zhu
Journal:  RSC Adv       Date:  2020-03-24       Impact factor: 4.036

10.  Shear bond strength between alumina substrate and prosthodontic resin composites with various adhesive resin systems.

Authors:  Yousef A AlJehani; Jagan K Baskaradoss; Amrita Geevarghese; Marey A AlShehry; Pekka K Vallittu
Journal:  BMC Oral Health       Date:  2015-05-02       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.