Measurements of morning and evening airflow grossly underestimate the circadian variability of FEV1 and peak expiratory flow rate in asthma.

G E D'Alonzo1, V W Steinijans, A Keller.   

Abstract

Peak expiratory flow rate (PEF) or forced expiratory volume in 1 s (FEV1) monitoring is an important clinical tool to assess the degree of 24-h variation (circadian) in lung function, which correlates with the degree of airway hyperresponsiveness. Ideally, PEF measurements should be taken frequently during the 24-h period to reflect the true variability. In practice, however, measurements are generally taken twice daily, usually upon arising and in the evening before bedtime. The effect of reducing the frequency of lung function measurement on the reported 24-h time average (mesor) and the circadian variability were evaluated. Four measurements taken 8 h apart and two measurements derived upon arising and the other, either 12 h later or before retiring, were compared with the full 24-h lung function profile, which included thirteen 2-hourly measurements. Based on the data from a 24-h lung function study in 20 adult patients with asthma, the corresponding values were separately compared at baseline and under two theophylline treatments, one being administered twice daily and the other once daily. The results are as follows: Whereas the 24-h time average (mesor) is hardly effected by the reduced measurements schemes, variability was grossly underestimated. Only 60 to 80% of the actual variability is picked up in the case of the four 8-hourly measurements, and only 20 to 45% in the case of the two measurements. The loss of accuracy in assessing 24-h airflow variability has potentially important implications on clinical practice and the investigation of therapeutics in asthma.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7663789     DOI: 10.1164/ajrccm.152.3.7663789

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  5 in total

1.  Diurnal variability--time to change asthma guidelines?

Authors:  H Reddel; C Jenkins; A Woolcock
Journal:  BMJ       Date:  1999-07-03

2.  Effect of the number of peak expiratory flow readings per day on the estimation of diurnal variation.

Authors:  P F Gannon; D T Newton; C F Pantin; P S Burge
Journal:  Thorax       Date:  1998-09       Impact factor: 9.139

Review 3.  Breathing around the clock: an overview of the circadian pattern of respiration.

Authors:  Jacopo P Mortola
Journal:  Eur J Appl Physiol       Date:  2003-10-21       Impact factor: 3.078

4.  Reduced Cross-Shift Lung Function and Respiratory Symptoms among Integrated Textile Factory Workers in Ethiopia.

Authors:  Yifokire Tefera Zele; Abera Kumie; Wakgari Deressa; Bente E Moen; Magne Bråtveit
Journal:  Int J Environ Res Public Health       Date:  2020-04-16       Impact factor: 3.390

Review 5.  Asthma diagnosis: into the fourth dimension.

Authors:  Ran Wang; Clare S Murray; Stephen J Fowler; Angela Simpson; Hannah Jane Durrington
Journal:  Thorax       Date:  2021-01-27       Impact factor: 9.139

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.