Literature DB >> 7661259

Clinical experience with the Leeds-Keio artificial ligament in anterior cruciate ligament reconstruction. A prospective two-year follow-up study.

J Rading1, L Peterson.   

Abstract

In this study, 24 consecutive patients with symptomatic chronic anterior cruciate ligament ruptures who had ligament reconstructions with the Leeds-Keio artificial ligament were observed for a minimum of 2 years or until ligament failure, whichever came first. The evaluation included a clinical examination, Lysholm knee score, and testing with a KT-1000 arthrometer. Within 2 years after surgery three patients underwent reoperation because of a rupture of the artificial ligament leading to instability. Another six patients developed significant subjective instability, even during ordinary activity. Only eight patients had a subjectively stable knee. Eleven patients scored 84 points or less on the Lysholm knee score, and 13 patients scored 85 points or more. The mean difference in anterior translation between the reconstructed knee and the opposite knee tested with the KT-1000 arthrometer was 3.7 mm. The high incidence of unstable knees, 9 of 24, due to insufficiency of the artificial ligament in this 2-year follow-up study strongly suggests that the Leeds-Keio artificial ligament is not an effective device for the reconstruction of the anterior cruciate ligament.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7661259     DOI: 10.1177/036354659502300311

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  13 in total

1.  Long-term results of a randomized study on anterior cruciate ligament reconstruction with or without a synthetic degradable augmentation device to support the autograft.

Authors:  Lars Peterson; Ulf Eklund; Björn Engström; Magnus Forssblad; Tönu Saartok; Anders Valentin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-31       Impact factor: 4.342

Review 2.  ACL prosthesis: any promise for the future?

Authors:  Saccomanni Bernardino
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-11-14       Impact factor: 4.342

3.  Ligament regeneration using an absorbable stent-shaped poly-L-lactic acid scaffold in a rabbit model.

Authors:  Hanako Nishimoto; Takeshi Kokubu; Atsuyuki Inui; Yutaka Mifune; Kotaro Nishida; Hiroyuki Fujioka; Kumiko Yokota; Chiaki Hiwa; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2012-09-14       Impact factor: 3.075

Review 4.  Anterior cruciate ligament reconstruction with synthetic grafts. A review of literature.

Authors:  Claudio Legnani; Alberto Ventura; Clara Terzaghi; Enrico Borgo; Walter Albisetti
Journal:  Int Orthop       Date:  2010-02-16       Impact factor: 3.075

5.  Primary ACL reconstruction using the LARS device is associated with a high failure rate at minimum of 6-year follow-up.

Authors:  Scott John Tulloch; Brian Meldan Devitt; Tabitha Porter; Taylor Hartwig; Haydn Klemm; Sam Hookway; Cameron John Norsworthy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-03-22       Impact factor: 4.342

Review 6.  Scaffolds for tendon and ligament repair and regeneration.

Authors:  Anthony Ratcliffe; David L Butler; Nathaniel A Dyment; Paul J Cagle; Christopher S Proctor; Seena S Ratcliffe; Evan L Flatow
Journal:  Ann Biomed Eng       Date:  2015-02-04       Impact factor: 3.934

7.  Studies of polyurethane urea bands for ACL reconstruction.

Authors:  Elisabeth Liljensten; Katrin Gisselfält; Bengt Edberg; Hans Bertilsson; Per Flodin; Anders Nilsson; Anders Lindahl; Lars Peterson
Journal:  J Mater Sci Mater Med       Date:  2002-04       Impact factor: 3.896

Review 8.  Anterior cruciate ligament reconstruction best practice: A review of graft choice.

Authors:  Daniel A Shaerf; Philip S Pastides; Khaled M Sarraf; Charles A Willis-Owen
Journal:  World J Orthop       Date:  2014-01-18

9.  Anterior cruciate ligament reconstruction: a look at prosthetics--past, present and possible future.

Authors:  Randy Mascarenhas; Peter B MacDonald
Journal:  Mcgill J Med       Date:  2008-01

Review 10.  Status and headway of the clinical application of artificial ligaments.

Authors:  Tianwu Chen; Jia Jiang; Shiyi Chen
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2015-02-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.