Suture sinus formation following closure of ventral midline incisions with polypropylene in three horses.

S S Trostle1, D A Hendrickson.   

Abstract

Suture sinuses formed in 3 horses following closure of ventral midline incisions with size-2 polypropylene. Suture sinuses healed after the suture material was removed. Suture sinus formation following closure with polypropylene may be related to the suture material's mechanical, rather than its chemical, properties. If polypropylene is used to close the linea alba in horses, the amount of tissue incorporated in the suture loops, suture tension, and knot volume should be minimized to decrease the risk of suture sinus formation.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7657574

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  1 in total

1.  Comparison of incisional complications between skin closures using a simple continuous or intradermal pattern: a pilot study in horses undergoing ventral median celiotomy.

Authors:  Doreen Scharner; Claudia Gittel; Karsten Winter; Dominique Blaue; Carola Schedlbauer; Ingrid Vervuert; Walter Brehm
Journal:  PeerJ       Date:  2018-11-09       Impact factor: 2.984