Literature DB >> 7653634

Advantages of continuous measurement of cardiac output 24 h a day.

J P Montani1, H L Mizelle, B N Van Vliet, T H Adair.   

Abstract

To test the hypothesis that continuous measurement of cardiac output 24 h a day would provide a better day-by-day reproducibility of the daily average cardiac output than acute measurements, we developed a computer-assisted method to monitor cardiac output continuously using an electromagnetic flow transducer. Because the diastolic aortic flow, which is used as a zero-flow reference, can drift significantly with electromagnetic flow probes, automatic tracking of the diastolic flow baseline was considered essential for long-term measurements. To accomplish this, the analog pulsatile flow signal was digitally converted and processed by an IBM PC to correct for signal drift on a beat-per-beat basis. Using this computerized system in 19 chronically instrumented dogs, we compared the values of cardiac output during 5 consecutive control days, measured either for 20 h each day (allowed 4 h for special care) or for 30 min in the morning when the trained dogs were required to lie quietly in their cages. The results show that the coefficient of variation of the five daily averages in cardiac output for each individual dog was three times smaller when cardiac output was measured 20 h each day (2.9 +/- 0.3 vs. 9.7 +/- 1.0%). Whole-day coefficients of variation were also smaller for mean arterial pressure, heart rate, stroke volume, and total peripheral resistance. Because of this greater day-by-day reproducibility, continuous monitoring of cardiac output is likely to be more sensitive to small changes in cardiac output induced by experimental protocols.

Entities:  

Mesh:

Year:  1995        PMID: 7653634     DOI: 10.1152/ajpheart.1995.269.2.H696

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  5 in total

1.  Contribution of baroreceptors and chemoreceptors to ventricular hypertrophy produced by sino-aortic denervation in rats.

Authors:  B N Van Vliet; L L Chafe; J P Montani
Journal:  J Physiol       Date:  1999-05-01       Impact factor: 5.182

2.  Reproducibility assessment of a multiple reference tissue method for quantitative dynamic contrast enhanced-MRI analysis.

Authors:  Cheng Yang; Gregory S Karczmar; Milica Medved; Aytekin Oto; Marta Zamora; Walter M Stadler
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

3.  Effects of a diet high in salt, fat, and sugar on telemetric blood pressure measurements in conscious, unrestrained adult Yucatan miniature swine (Sus scrofa).

Authors:  Semone B Myrie; Leslie L McKnight; J Christopher King; John J McGuire; Bruce N Van Vliet; Robert F Bertolo
Journal:  Comp Med       Date:  2012-08       Impact factor: 0.982

4.  Validation of a computational platform for the analysis of the physiologic mechanisms of a human experimental model of hemorrhage.

Authors:  Richard L Summers; Kevin R Ward; Tarynn Witten; Victor A Convertino; Kathy L Ryan; Thomas G Coleman; Robert L Hester
Journal:  Resuscitation       Date:  2009-10-04       Impact factor: 5.262

5.  Sustained suppression of sympathetic activity and arterial pressure during chronic activation of the carotid baroreflex.

Authors:  Thomas E Lohmeier; Radu Iliescu; Terry M Dwyer; Eric D Irwin; Adam W Cates; Martin A Rossing
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-05-28       Impact factor: 4.733

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.