Literature DB >> 7652018

An improved design for a stable and reproducible phantom material for use in near-infrared spectroscopy and imaging.

M Firbank1, M Oda, D T Delpy.   

Abstract

In this note, we describe an improved phantom material for use in near-infrared spectroscopy and imaging. The material consists of a clear epoxy resin with absorbing dyes and amorphous silica spheres as scattering particles. It is possible to calculate the scattering coefficient and angular scattering distribution of the material from Mie theory, using the known size and refractive index of the silica spheres together with the measured refractive index of the resin (approximately 1.56). We show a good agreement between prediction and experimental measurements. The scattering properties of the material closely match those of tissue in the near-infrared wavelength region, having an anisotropy factor, g, of approximately 0.93. The absorption coefficient of the epoxy is low (approximately 0.001 mm-1), and addition of the dyes produces an absorption coefficient that covers the same range as that of tissue.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7652018     DOI: 10.1088/0031-9155/40/5/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Analytical method for the fast time-domain reconstruction of fluorescent inclusions in vitro and in vivo.

Authors:  Sung-Ho Han; Salman Farshchi-Heydari; David J Hall
Journal:  Biophys J       Date:  2010-01-20       Impact factor: 4.033

2.  Brain tissue phantoms for optical near infrared imaging.

Authors:  K Prahlad Rao; S Radhakrishnan; M Ramasubba Reddy
Journal:  Exp Brain Res       Date:  2005-12-09       Impact factor: 1.972

3.  Spatial sensitivity and penetration depth of three cerebral oxygenation monitors.

Authors:  Sonny Gunadi; Terence S Leung; Clare E Elwell; Ilias Tachtsidis
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

4.  Anti-confocal assessment of middle ear inflammation.

Authors:  David S Jung; John A Crowe; John P Birchall; Michael G Somekh; Chung W See
Journal:  Biomed Opt Express       Date:  2016-12-12       Impact factor: 3.732

5.  Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy.

Authors:  Afrina Mustari; Izumi Nishidate; Md Abdul Wares; Takaaki Maeda; Satoko Kawauchi; Shunichi Sato; Manabu Sato; Yoshihisa Aizu
Journal:  J Vis Exp       Date:  2018-08-22       Impact factor: 1.355

6.  Dependence of optical scattering from Intralipid in gelatin-gel based tissue-mimicking phantoms on mixing temperature and time.

Authors:  Puxiang Lai; Xiao Xu; Lihong V Wang
Journal:  J Biomed Opt       Date:  2014-03       Impact factor: 3.170

7.  Plastinated tissue samples as three-dimensional models for optical instrument characterization.

Authors:  Daniel L Marks; Eric J Chaney; Stephen A Boppart
Journal:  Opt Express       Date:  2008-09-29       Impact factor: 3.894

8.  Dynamic contrast-enhanced diffuse optical tomography (DCE-DOT): experimental validation with a dynamic phantom.

Authors:  Mehmet Burcin Unlu; Yuting Lin; Gultekin Gulsen
Journal:  Phys Med Biol       Date:  2009-10-20       Impact factor: 3.609

9.  Low-cost tissue simulating phantoms with adjustable wavelength-dependent scattering properties in the visible and infrared ranges.

Authors:  Rolf B Saager; Alan Quach; Rebecca A Rowland; Melissa L Baldado; Anthony J Durkin
Journal:  J Biomed Opt       Date:  2016-06-01       Impact factor: 3.170

10.  In vivo spatial frequency domain spectroscopy of two layer media.

Authors:  Dmitry Yudovsky; John Quan M Nguyen; Anthony J Durkin
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.