Literature DB >> 7652010

Measurement of patient entrance surface dose rates for fluoroscopic x-ray units.

C J Martin1.   

Abstract

Measurements of patient entrance surface dose rate provide valuable data for interpreting results from dose-area product studies on fluoroscopic x-ray equipment. Methods for measurement of entrance surface dose rate with backscatter and incident dose rate without backscatter have been investigated. Entrance surface dose rate is measured with an ionization chamber in contact with a tissue-equivalent phantom. Backscattered radiation contributes 27-45% to the measurement and is affected by field size and chamber position. Incident dose rate measured using a copper phantom provides an alternative approach. Consistent relationships between thicknesses of Perspex and copper giving similar incident dose rates under automatic gain control have been established for different tube potentials with and without a grid. This allows measurements of incident dose rate made using copper to be linked to corresponding thicknesses of tissue-equivalent material. Since only a few millimetres of copper are required, contributions from backscatter can be minimized and transport of phantoms is simplified. Incident dose can be related to dose-area product and entrance surface dose derived using backscatter factors. Such measurements play a valuable role in interpreting patient dose data and recommending options to reduce patient dose.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7652010     DOI: 10.1088/0031-9155/40/5/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Monte Carlo investigation of backscatter point spread function for X-ray imaging examinations.

Authors:  Zhenyu Xiong; Sarath Vijayan; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

2.  Calculation of the entrance skin dose distribution for fluoroscopically guided interventions using a pencil beam backscatter model.

Authors:  Sarath Vijayan; Zhenyu Xiong; Stephen Rudin; Daniel R Bednarek
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-14

3.  Skin dose mapping for non-uniform x-ray fields using a backscatter point spread function.

Authors:  Sarath Vijayan; Zhenyu Xiong; Alok Shankar; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

4.  STROBE--Radiation Ulcer: An Overlooked Complication of Fluoroscopic Intervention: A Cross-Sectional Study.

Authors:  Kai-Che Wei; Kuo-Chung Yang; Guang-Yuan Mar; Lee-Wei Chen; Chieh-Shan Wu; Chi-Cheng Lai; Wen-Hua Wang; Ping-Chin Lai
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.