Literature DB >> 7651114

MR microscopy of the rat carotid artery after balloon injury by using an implanted imaging coil.

R M Summers1, L W Hedlund, G P Cofer, M B Gottsman, J F Manibo, G A Johnson.   

Abstract

Neointimal hyperplasia after angioplasty was followed in vivo in rats by using MR microscopy and surgically implanted RF imaging coils. By using an inductively coupled pick-up coil, the arteries were imaged 4 days before and 3, 7, and 14 days after angioplasty with a 3DFT spin echo sequence. Eight of 10 angioplastied rats showed moderate to severe stensois based MR measures of lumen diameter reduction from baseline images. There was a good correlation between total wall thickness between MR and hematoxylin and eosin (H&E)-stained sections obtained on the last day. Arteries in the intact and sham groups remained unchanged from baseline measurements. Because this imaging technique examines the artery under in vivo conditions of arterial pressure and flow, it promises to be a useful tool for evaluating pharmacological and mechanical methods of reducing the incidence of vascular stenosis.

Entities:  

Mesh:

Year:  1995        PMID: 7651114     DOI: 10.1002/mrm.1910330607

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

Review 1.  The neural basis of the blood-oxygen-level-dependent functional magnetic resonance imaging signal.

Authors:  Nikos K Logothetis
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2002-08-29       Impact factor: 6.237

Review 2.  Small animal imaging with magnetic resonance microscopy.

Authors:  Bastiaan Driehuys; John Nouls; Alexandra Badea; Elizabeth Bucholz; Ketan Ghaghada; Alexandra Petiet; Laurence W Hedlund
Journal:  ILAR J       Date:  2008

3.  Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil.

Authors:  Xiaoliang Zhang; Xiao-Hong Zhu; Runxia Tian; Yi Zhang; Hellmut Merkle; Wei Chen
Journal:  MAGMA       Date:  2003-07-04       Impact factor: 2.310

Review 4.  Engineering novel detectors and sensors for MRI.

Authors:  Chunqi Qian; Gary Zabow; Alan Koretsky
Journal:  J Magn Reson       Date:  2012-11-29       Impact factor: 2.229

5.  Cardiovascular magnetic resonance imaging in experimental models.

Authors:  Anthony N Price; King K Cheung; Jon O Cleary; Adrienne E Campbell; Johannes Riegler; Mark F Lythgoe
Journal:  Open Cardiovasc Med J       Date:  2010-11-26

6.  Wireless Reconfigurable RF Detector Array for Focal and Multiregional Signal Enhancement.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-07-24       Impact factor: 3.367

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.