In vivo validation of magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels.

M B Hofman1, F C Visser, A C van Rossum, Q M Vink, M Sprenger, N Westerhof.   

Abstract

The accuracy of magnetic resonance phase contrast volume flow measurements in small blood vessels is expected to be smaller than in large vessels, because of partial volume effects at the vessel boundary. Accuracy was validated in the dog femoral artery, diameter 3.5 +/- 0.7 mm, using an ultrasonic transit-time flowmeter (TT). The number of pixels per vessel diameter (ND) ranged from 1.6 to 4.8. The vessel cross-section was determined using a threshold in the magnitude image. Between the two methods the correlation coefficient was 0.95 (range 10-200 ml/min). The proportional difference (PD), (QTT-QMR)/1/2(QTT+QMR), was 0.8%, showing no systematic difference between the methods. The PDs standard deviation was 27%, and 19% for flow rates above 30 ml/min. Only a significant decrease of the PDs variance was found at the highest ND values, suggesting other sources of error than partial volume effects. It is concluded that with an ND value of about 3, accurate blood volume flow rates can be determined.

Entities:  

Mesh:

Year:  1995        PMID: 7651113     DOI: 10.1002/mrm.1910330606

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  In vivo evaluation of quantitative MR angiography in a canine carotid artery stenosis model.

Authors:  M Calderon-Arnulphi; S Amin-Hanjani; A Alaraj; M Zhao; X Du; S Ruland; X J Zhou; K R Thulborn; F T Charbel
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

2.  Changes in systemic and pulmonary blood flow distribution in normal adult volunteers in response to posture and exercise: a phase contrast magnetic resonance imaging study.

Authors:  Derek T H Wong; Kyong-Jin Lee; Shi-Joon Yoo; George Tomlinson; Lars Grosse-Wortmann
Journal:  J Physiol Sci       Date:  2014-01-03       Impact factor: 2.781

Review 3.  A practical approach to MRI of coronary artery bypass graft patency and flow.

Authors:  A C van Rossum; M A Galjee; J C Post; C A Visser
Journal:  Int J Card Imaging       Date:  1997-06

4.  Right coronary artery flow velocity and volume assessment with spiral K-space sampled breathhold velocity-encoded MRI at 3 tesla: accuracy and reproducibility.

Authors:  Anne Brandts; Stijntje D Roes; Joost Doornbos; Robert G Weiss; Albert de Roos; Matthias Stuber; Jos J M Westenberg
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

5.  Altered coronary endothelial function in young smokers detected by magnetic resonance assessment of myocardial blood flow during the cold pressor test.

Authors:  Yasutaka Ichikawa; Kakuya Kitagawa; Shingo Kato; Kaoru Dohi; Tadanori Hirano; Masaaki Ito; Hajime Sakuma
Journal:  Int J Cardiovasc Imaging       Date:  2014-02-12       Impact factor: 2.357

6.  Vertebrobasilar Flow Evaluation and Risk of Transient Ischaemic Attack and Stroke study (VERiTAS): rationale and design.

Authors:  Sepideh Amin-Hanjani; Linda Rose-Finnell; DeJuran Richardson; Sean Ruland; Dilip Pandey; Keith R Thulborn; David S Liebeskind; Gregory J Zipfel; Mitchell S V Elkind; Jeffrey Kramer; Frank L Silver; Scott E Kasner; Louis R Caplan; Colin P Derdeyn; Philip B Gorelick; Fady T Charbel
Journal:  Int J Stroke       Date:  2010-12       Impact factor: 5.266

7.  How is pulmonary arterial blood flow affected by pulmonary venous obstruction in children? A phase-contrast magnetic resonance study.

Authors:  Kevin S Roman; Christian J Kellenberger; Christopher K Macgowan; John Coles; Andrew N Redington; Lee N Benson; Shi-Joon Yoo
Journal:  Pediatr Radiol       Date:  2005-01-19

8.  An efficient full space-time discretization method for subject-specific hemodynamic simulations of cerebral arterial blood flow with distensible wall mechanics.

Authors:  Chang Sub Park; Ali Alaraj; Xinjian Du; Fady T Charbel; Andreas A Linninger
Journal:  J Biomech       Date:  2019-02-25       Impact factor: 2.712

9.  Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitions.

Authors:  Lau Brix; Steffen Ringgaard; Allan Rasmusson; Thomas Sangild Sørensen; W Yong Kim
Journal:  J Cardiovasc Magn Reson       Date:  2009-02-20       Impact factor: 5.364

10.  Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease.

Authors:  Sohrab Fratz; Taylor Chung; Gerald F Greil; Margaret M Samyn; Andrew M Taylor; Emanuela R Valsangiacomo Buechel; Shi-Joon Yoo; Andrew J Powell
Journal:  J Cardiovasc Magn Reson       Date:  2013-06-13       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.