Literature DB >> 7649513

[Clinical experiences with the torque-segmented arch (TSA)].

F G Sander1, A Wichelhaus.   

Abstract

The torque segmented archwire presented here led to a good torque transfer in all patients, however this transfer differed on a case by case basis. With regard to the angle 1-NA, the average monthly torque change was 2.34 degrees. The smallest torque transfer was 1 degree; the biggest 5.5 degrees per month. Because the torque segmented arch wires consist of a pseudoelastic material for the anterior teeth and a steel portion for the lateral teeth, the anterior component can be adapted to the patient's individual situation and in addition the lateral components make possible the bending of first, second and third order bends. The dimensions of the superelastic materials are 0.016 x 0.022, 0.017 x 0.025, and 0.018 x 0.025. In all 3 dimensions it is possible to select a torque of 30 degrees or 45 degrees. The use of such arch wires yields the following advantages: 1. Problem-free adaptation to the patient's individual situation. 2. Torque segmented arch wires can be applied in the case of the standard edgewise technique as well as in each case of the straight wire technique. 3. The practitioner is no longer dependent on the torque loss of the archwire and the individual axial position of the incisors. 4. With the help of the torque key it is possible at any time to control the already transferred torque with regard to the occlusal plane. 5. The torque segmented archwire can also be applied in the segmented archwire technique. 6. The torque segmented archwire with right angular or round lateral components is well suited for the retraction of the anterior area.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7649513     DOI: 10.1007/bf02168132

Source DB:  PubMed          Journal:  Fortschr Kieferorthop        ISSN: 0015-816X


  22 in total

1.  Possible etiologic factors in external root resorption.

Authors:  W G Newman
Journal:  Am J Orthod       Date:  1975-05

2.  Long-term evaluation of root resorption occurring during orthodontic treatment.

Authors:  D N Remington; D R Joondeph; J Artun; R A Riedel; M K Chapko
Journal:  Am J Orthod Dentofacial Orthop       Date:  1989-07       Impact factor: 2.650

3.  [Front torque using a partial arch technic].

Authors:  H P Bantleon; H Droschl
Journal:  Fortschr Kieferorthop       Date:  1988-04

4.  Root resorption in maxillary central incisors following active orthodontic treatment.

Authors:  S Copeland; L J Green
Journal:  Am J Orthod       Date:  1986-01

5.  Faciolingual tooth movement: its influence on the root and cortical plate.

Authors:  W M Wainwright
Journal:  Am J Orthod       Date:  1973-09

6.  A study of root resorption in treated Class II, Division I malocclusions.

Authors:  R W DeShields
Journal:  Angle Orthod       Date:  1969-10       Impact factor: 2.079

7.  A histologic study of the changes in tissues of the periodontium of the Rhesus monkey with the application of torque force in the third stage of the Begg technique.

Authors:  D R Ford
Journal:  Am J Orthod       Date:  1970-02

8.  Apical root resorption in upper anterior teeth.

Authors:  B O Linge; L Linge
Journal:  Eur J Orthod       Date:  1983-08       Impact factor: 3.075

9.  The effect of extraction and orthodontic treatment on dentoalveolar support.

Authors:  D B Kennedy; D R Joondeph; S K Osterberg; R M Little
Journal:  Am J Orthod       Date:  1983-09

10.  Patient characteristics and treatment variables associated with apical root resorption during orthodontic treatment.

Authors:  L Linge; B O Linge
Journal:  Am J Orthod Dentofacial Orthop       Date:  1991-01       Impact factor: 2.650

View more
  3 in total

1.  Intrusion mechanics according to Burstone with the NiTi-SE-steel uprighting spring.

Authors:  F G Sander; A Wichelhaus; C Schiemann
Journal:  J Orofac Orthop       Date:  1996-08       Impact factor: 1.938

2.  Concept and development of a measuring system for in vivo recording of orthodontically applied forces and torques in the multiband technique. Part I.

Authors:  N Rosarius; D Friedrich; R Fuhrmann; G Rau; P Diedrich
Journal:  J Orofac Orthop       Date:  1996-10       Impact factor: 1.938

3.  Stainless steel and NiTi torque archwires and apical root resorption.

Authors:  Andrea Wichelhaus; Marc Dulla; Hisham Sabbagh; Uwe Baumert; Thomas Stocker
Journal:  J Orofac Orthop       Date:  2020-09-01       Impact factor: 1.938

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.