Literature DB >> 7648587

Venography with carbon dioxide as a contrast agent.

K L Sullivan1, J Bonn, M J Shapiro, G A Gardiner.   

Abstract

PURPOSE: The purpose of this study was to evaluate the feasibility, safety, and potential role of carbon dioxide (CO2) as a contrast agent for venography.
METHODS: Consecutive patients with contraindications to iodinated contrast agents or with unsatisfactory iodinated contrast studies underwent CO2 digital subtraction venography. The images were rated by three experienced angiographers. Image quality and complications were assessed.
RESULTS: Over a 14-month period, 66 vein segments were studied in 21 patients. There was good correlation between experienced angiographers on CO2 image quality (Ri = 0.80) and good agreement on diagnosis (k = 0.62). In 91% of the vein segments evaluated with C02 there was interobserver agreement on the diagnosis. Upper extremity veins were adequately imaged with CO2 alone in all (6/6) patients with contraindications to iodinated contrast. Following suboptimal iodinated contrast studies in six patients, CO2 produced significantly better quality upper extremity central vein images (p < 0.05). Pain following injection into peripheral veins was the only CO2-related complication. Inferior vena cava (IVC) filters were successfully deployed with CO2 alone in 78% (7/9) of patients; two required iodinated contrast.
CONCLUSIONS: Based upon initial experience, CO2 venography can be recommended in patients with contraindications to iodinated contrast or unsatisfactory iodinated contrast studies.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7648587     DOI: 10.1007/bf00204138

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  9 in total

1.  Measuring agreement between two judges on the presence or absence of a trait.

Authors:  J L Fleiss
Journal:  Biometrics       Date:  1975-09       Impact factor: 2.571

2.  Comparison of air, oxygen and carbon dioxide embolization.

Authors:  A KUNKLER; H KING
Journal:  Ann Surg       Date:  1959-01       Impact factor: 12.969

3.  Carbon dioxide embolism: successful resuscitation with cardiopulmonary bypass.

Authors:  T A Diakun
Journal:  Anesthesiology       Date:  1991-06       Impact factor: 7.892

4.  The effect of verification on the assessment of imaging techniques 1983.

Authors:  G Revesz; H L Kundel; M Bonitatibus
Journal:  Invest Radiol       Date:  1990-04       Impact factor: 6.016

5.  Carbon dioxide embolism during laparoscopy.

Authors:  O F Yacoub; I Cardona; L A Coveler; M G Dodson
Journal:  Anesthesiology       Date:  1982-12       Impact factor: 7.892

6.  Carbon dioxide cineangiocardiography in the diagnosis of pericardial disease.

Authors:  A F Turner; H I Meyers; G Jacobson; W Lo
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1966-06

7.  Follow-up evaluation after renal artery bypass surgery with use of carbon dioxide arteriography and color-flow duplex scanning.

Authors:  T R Harward; S Smith; I F Hawkins; J M Seeger
Journal:  J Vasc Surg       Date:  1993-07       Impact factor: 4.268

8.  Capnography in the early diagnosis of carbon dioxide embolism during laparoscopy.

Authors:  D Shulman; H B Aronson
Journal:  Can Anaesth Soc J       Date:  1984-07

9.  Clinical applications of carbon dioxide/digital subtraction arteriography.

Authors:  F A Weaver; M J Pentecost; A E Yellin; S Davis; E Finck; G Teitelbaum
Journal:  J Vasc Surg       Date:  1991-02       Impact factor: 4.268

  9 in total
  1 in total

1.  CO(2) wedged hepatic venography in the evaluation of portal hypertension.

Authors:  W Debernardi-Venon; J C Bandi; J C García-Pagán; E Moitinho; V Andreu; M Real; A Escorsell; X Montanyá; J Bosch
Journal:  Gut       Date:  2000-06       Impact factor: 23.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.