Literature DB >> 7645711

Comparison between two fibrescopes with different diameter insertion cords for fibreoptic intubation.

P Hakala1, T Randell.   

Abstract

Two fibreoptic bronchoscopes with insertion cords of different diameters (3.7 and 5.0 mm) were compared during fibreoptic intubation in 84 adult patients (ASA 1-2) undergoing orotracheal intubation under general anaesthesia. The fibrescope used was randomly selected. The incidence of resistance to passage of the tracheal tube through the vocal cords was higher using the thinner fibrescope, 14/40 (35%) as compared with the thicker fibrescope, 5/44 (11%) (p < 0.05). Intubation failed with the thinner fibrescope in 8/40 (20%) of patients, whereas all intubations with the thicker fibrescope were successful in six patients after manipulation of the tracheal tube (p < 0.01). With the thinner fibrescope manipulation of the tracheal tube after impingement led to intubation of the trachea in 6/14 (43%) patients. The duration of intubation was significantly shorter with the thicker fibrescope (p < 0.05). There were two instances of oesophageal intubation with the thinner fibrescope. A fibrescope with a thicker insertion cord is more suitable for orotracheal fibreoptic intubation in adult patients.

Entities:  

Mesh:

Year:  1995        PMID: 7645711     DOI: 10.1111/j.1365-2044.1995.tb06108.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  7 in total

1.  Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-.

Authors:  Guen Seok Choi; Sang Il Park; Eun Ha Lee; Seok Hwa Yoon
Journal:  Korean J Anesthesiol       Date:  2010-12-31

2.  [Intubation with a tube exchanger on an intubation trainer. Influence of tube tip position on successful intubation].

Authors:  M Kemper; T Haas; S Imach; M Weiss
Journal:  Anaesthesist       Date:  2014-07-02       Impact factor: 1.041

3.  Role of endotracheal tube size on nasal and laryngeal morbidity during awake fiberoptic nasotracheal intubation: A Randomized controlled trial.

Authors:  Stalin Vinayagam; Thirumurugan Arikrishnan; Pankaj Kundra; Sunil Kumar Saxena
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-12-01

4.  Fibreoptic Orotracheal Intubation of Obese Patients Using Parker Flex-Tip vs. Standard Endotracheal Tube.

Authors:  Lee C Chang; Susan C Lee; Andrew L Ding; Suman Rajagopalan
Journal:  Turk J Anaesthesiol Reanim       Date:  2019-05-20

5.  Successful anesthetic management of a large supraglottic cyst.

Authors:  Harshal D Wagh
Journal:  Saudi J Anaesth       Date:  2014-07

6.  Failed fibreoptic intubation: 70° rigid nasendoscope and Frova introducer to the rescue.

Authors:  Stalin Vinayagam; Mvs Satya Prakash; Pankaj Kundra; Surianarayana Gopalakrishnan
Journal:  Indian J Anaesth       Date:  2016-07

7.  A cohort evaluation of clinical use and performance characteristics of Ambu® AuraGain™: A prospective observational study.

Authors:  Devangi A Parikh; Ruchi A Jain; Smita S Lele; Bharati A Tendolkar
Journal:  Indian J Anaesth       Date:  2017-08