Literature DB >> 7645706

Severe airway management problems during insertion of a cuffed oesophageal stent.

B T Langham1, I M McLaren.   

Abstract

A 68-year-old man underwent a general anaesthetic for insertion of an oesophageal stent for a tracheo-oesophageal fistula. The authors report the management of severe airway problems caused by the insertion of the stent and discuss the use of a double lumen tube in this situation.

Entities:  

Mesh:

Year:  1995        PMID: 7645706     DOI: 10.1111/j.1365-2044.1995.tb06103.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  1 in total

1.  Sealing of tracheoesophageal fistula using a Y stent through fiberoptic bronchoscope during general anesthesia under laryngeal mask airway.

Authors:  Ling Ye; Pingliang Yang; Yunxia Zuo
Journal:  Int J Clin Exp Med       Date:  2014-12-15
  1 in total