In vivo assessment of catheter-tip PO2 sensor: sampling lumen fabrication.

A Spencer1, P Rolfe, A Murphy, T Wright, S McKenna.   

Abstract

Fabrication of the sampling lumen of an intra-arterial PO2 sensor is performed in standard catheters mechanically or by laser. Clinical evaluation is performed with respect to catheter insertion, complications, accuracy of oxygen sensor data and fibrin deposition on the catheter surface. The success rate for catheter insertion is 57% for 138 standard and 50% for 74 laser-cut catheters studied. The proportion of catheter failures (blocked or non-reading) is 14% in laser-cut compared with 30% in standard. These differences are not statistically significant at the 5% level. There is no clinically significant difference in sensor accuracy, with 37.5% of results within +/- 0.05 kPa and 80% within +/- 2.0 kPa of simultaneous blood gas values. Drift is within +/- 0.3 kPa h-1 for 78% of monitoring time. Significant errors of recalibration occur in 6% of calibrations. Scanning electron micrographs demonstrate a much smaller sampling lumen in the laser-cut group, but no reduction in fibrin deposition at the site of the sampling hole. The low success rate for catheter insertion is a problem because of cost implications. The accuracy of the system is usually sufficient for clinical purposes, provided the calibration is checked every 4 h.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7643653     DOI: 10.1007/bf02523034

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  7 in total

1.  Continuous monitoring of arterial oxygen tension using a catheter-tip polarographic electrode in infants.

Authors:  M Conway; G M Durbin; D Ingram; N McIntosh; D Parker; E O Reynolds; L P Soutter
Journal:  Pediatrics       Date:  1976-02       Impact factor: 7.124

2.  Review of chemical sensors for physiological measurement.

Authors:  P Rolfe
Journal:  J Biomed Eng       Date:  1988-04

3.  Experience with a catheter-tip transducer for continuous measurement of blood oxygen tension, including evaluation in 4 newborn babies.

Authors:  P Goddard; I Keith; H Marcovitch; P J Rolfe
Journal:  Arch Dis Child       Date:  1972-08       Impact factor: 3.791

4.  Use of a continuously recording intravascular oxygen electrode in the newborn.

Authors:  P Goddard; I Keith; H Marcovitch; N R Roberton; P Rolfe; J W Scopes
Journal:  Arch Dis Child       Date:  1974-11       Impact factor: 3.791

5.  Prevention of platelet adhesion and aggregation by a glutardialdehyde-stabilized heparin surface.

Authors:  P Olsson; H Lagergren; R Larsson; K Rådegran
Journal:  Thromb Haemost       Date:  1977-04-30       Impact factor: 5.249

6.  Possible contributions of surface energy and interfacial parameters of synthetic polymers to blood compatibility.

Authors:  C P Sharma
Journal:  Biomaterials       Date:  1981-01       Impact factor: 12.479

7.  Excessive handling as a cause of hypoxemia.

Authors:  J G Long; A G Philip; J F Lucey
Journal:  Pediatrics       Date:  1980-02       Impact factor: 7.124

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.