Literature DB >> 7642326

A comparison of the apical dye penetration patterns shown by methylene blue and india ink in root-filled teeth.

K M Ahlberg1, P Assavanop, W M Tay.   

Abstract

This study compared the linear leakage patterns shown by 5% aqueous solution of methylene blue (MB) and India ink (II). One-hundred and twenty-five roots with single canals from extracted human teeth were used. The canals were cleaned and shaped using the step-back technique under copious irrigation. Three groups were arranged to receive root fillings of gutta-percha and one of three proprietary sealers using standard lateral condensation techniques: Sealapex (40 roots), Tubli-Seal (40 roots) and Ketac-Endo (20 roots). The remaining roots were used as controls: positive with gutta-percha and no sealer and negative with the apices sealed with nail varnish. The roots were randomly selected for 7-day immersion in either MB or II, then sectioned longitudinally; dye penetration was assessed using a Wild Leitz stereomicroscope. In all groups MB showed more penetration than II. The results were statistically significant at the P = 0.01 level, with the exception of the positive control groups. Negative controls showed no penetration. It is concluded that MB, which has a low molecular weight penetrated more deeply along root canal fillings than II, which has a large particle size.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7642326     DOI: 10.1111/j.1365-2591.1995.tb00153.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  14 in total

1.  Assessment of different dyes used in leakage studies.

Authors:  Johannes Mente; Stephan Ferk; Jens Dreyhaupt; Andreas Deckert; Milos Legner; Hans Joerg Staehle
Journal:  Clin Oral Investig       Date:  2009-06-18       Impact factor: 3.573

2.  Evaluation of the effect of tracer pH on the sealing ability of glass ionomer cement and mineral trioxide aggregate.

Authors:  Josette Camilleri; Thomas R Pitt Ford
Journal:  J Mater Sci Mater Med       Date:  2008-03-25       Impact factor: 3.896

3.  Stereomicroscopic Dye Leakage Measurement of Six Different Root Canal Sealers.

Authors:  Srinidhi V Ballullaya; Vusurumarthi Vinay; Jayaprakash Thumu; Srihari Devalla; Indira Priyadarshini Bollu; Sagarika Balla
Journal:  J Clin Diagn Res       Date:  2017-06-01

4.  Effect of Synthetic Tissue Fluid on Microleakage of Grey and White Mineral Trioxide Aggregate as Root-End Filling Materials: An in vitro study.

Authors:  Mehrdad Lotfi; Sepideh Vosoughhosseini; Mohammad Ali Saghiri; Saeed Rahimi; Vahid Zand; Mohammad Forough Reyhani; Mohammad Samiei; Negin Ghasemi; Payman Mehrvarzfar; Shahram Azimi; Noushin Shokohinejad
Journal:  Sultan Qaboos Univ Med J       Date:  2012-07-15

5.  An in vitro comparison of coronal microleakage of three orifice barriers filling materials.

Authors:  Hamidreza Yavari; Mohammad Samiei; Mahsa Eskandarinezhad; Shahriar Shahi; Marzieh Aghazadeh; Yones Pasvey
Journal:  Iran Endod J       Date:  2012-08-01

6.  Evaluating the Effect of Resection on the Sealing Ability of MTA and CEM Cement.

Authors:  Amin Salem Milani; Sahar Shakouie; Zahra Borna; Alireza Sighari Deljavan; Mohammad Asghari Jafarabadi; Fatemeh Pournaghi Azar
Journal:  Iran Endod J       Date:  2012-08-01

7.  Evaluation of apical leakage in root canals obturated with three different sealers in presence or absence of smear layer.

Authors:  Hadi Mokhtari; Shahriar Shahi; Maryam Janani; Mohammad Frough Reyhani; Hamid Reza Mokhtari Zonouzi; Saeed Rahimi; Hamid Reza Sadr Kheradmand
Journal:  Iran Endod J       Date:  2015-03-18

8.  The Effect of One-Step or Two-Step MTA Plug and Tooth Apical Width on Coronal Leakage in Open Apex Teeth.

Authors:  Zohreh Khalilak; Tabasom Vali; Farzad Danesh; Mehdi Vatanpour
Journal:  Iran Endod J       Date:  2012-03-01

9.  Comparative evaluation of intracanal sealing ability of mineral trioxide aggregate and glass ionomer cement: An in vitro study.

Authors:  Gauri Malik; Poonam Bogra; Simranjeet Singh; Rupandeep K Samra
Journal:  J Conserv Dent       Date:  2013-11

10.  Copper ion as a new leakage tracer.

Authors:  J Modaresi; M Baharizade; A Shareghi; M Ahmadi; A Daneshkazemi
Journal:  J Dent (Shiraz)       Date:  2013-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.