Literature DB >> 7634756

Accuracy of breath-by-breath analysis of flow-volume loop in identifying sleep-induced flow-limited breathing cycles in sleep apnoea-hypopnoea syndrome.

F Sériès1, I Marc.   

Abstract

1. Inspiratory flow limitation is involved in the pathophysiology of sleep-related breathing disorders. Since the definition of flow-limited cycle is based on a dissociation between flow and respiratory efforts, identification of inspiratory flow limitation requires upper airway or intrathoracic pressure measurements. We examined the accuracy of the analysis of the flow-volume loop of a tidal breath in identifying inspiratory flow limitation during sleep in ten patients with a sleep apnoea-hypopnoea syndrome. 2. Measurements were taken during continuous positive airway pressure trials. After data acquisition, the presence of inspiratory flow limitation was identified by the presence of an inspiratory plateau or decrease in inspiratory flow independently of the increase in inspiratory efforts. The flow-volume loop was reconstructed for each breathing cycle by plotting the instantaneous flow and the tidal volume. The instantaneous inspiratory and expiratory flows were measured at 50% of the respective portion of the tidal volume, and a breath-by-breath analysis of the mid-tidal volume-flow ratio (inspiratory/expiratory ratio) was obtained. The analysis of the flow-volume loop was compared with standard inspiratory flow limitation criteria using different values of the inspiratory/expiratory ratio threshold, below which breathing cycles were classified as flow-limited. With a lower limit of the normal inspiratory/expiratory ratio threshold of 0.97, the sensitivity and specificity of the method were both 76%. In each subject, the proportion of breathing cycles identified as flow-progressively decreased with an increasing positive pressure level.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7634756     DOI: 10.1042/cs0880707

Source DB:  PubMed          Journal:  Clin Sci (Lond)        ISSN: 0143-5221            Impact factor:   6.124


  4 in total

1.  Automatic breath-to-breath analysis of nocturnal polysomnographic recordings.

Authors:  P J van Houdt; P P W Ossenblok; M G van Erp; K E Schreuder; R J J Krijn; P A J M Boon; P J M Cluitmans
Journal:  Med Biol Eng Comput       Date:  2011-03-30       Impact factor: 2.602

2.  Sleep related expiratory obstructive apnea in children.

Authors:  Mark E Haupt; Denise M Goodman; Stephen H Sheldon
Journal:  J Clin Sleep Med       Date:  2012-12-15       Impact factor: 4.062

3.  Pulmonary function and sleep apnea.

Authors:  Victor Hoffstein; Zoe Oliver
Journal:  Sleep Breath       Date:  2003-12       Impact factor: 2.816

4.  Validation of forehead venous pressure as a measure of respiratory effort for the diagnosis of sleep apnea.

Authors:  Djordje Popovic; Christopher King; Melanie Guerrero; Daniel J Levendowski; Delmer Henninger; Philip R Westbrook
Journal:  J Clin Monit Comput       Date:  2008-12-31       Impact factor: 2.502

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.