The acetabular T-type fracture. A biomechanical evaluation of internal fixation.

P T Simonian1, M L Routt, R M Harrington, A F Tencer.   

Abstract

The purpose of this study was to evaluate the stability of different types of internal fixation requiring anterior, posterior, or combined surgical approaches for the T-type acetabular fracture. Eight specimens were loaded 25 times in a cyclic manner to 150 N for each type of fixation construct evaluated. The model attempted to range the hip through an arc of motion anticipated in the limited activities expected after surgery. Strain gauges were placed on the 3 fracture planes of the T-type fracture. These gauges measured displacements. Internal fixation consisted of a single anterior column plate, compared with a single posterior column plate, compared with simultaneous placement of both anterior column and posterior column plates. The differences in displacements measured between the 3 types of fixation at each of the 3 fracture sites were not statistically significant. In evaluating motion at the anterior fracture line, the anterior plate made the largest contribution to stability, although this result was not statistically significant. The posterior plate similarly contributed most to posterior fracture stability, although again not statistically significant. Each of the 3 fixations controlled the inferior fracture line motions in a comparable manner.

Entities:  

Mesh:

Year:  1995        PMID: 7634640

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

Review 1.  [Biomechanical principles for treatment of osteoporotic fractures of the pelvis].

Authors:  A Gänsslen
Journal:  Unfallchirurg       Date:  2010-04       Impact factor: 1.000

2.  A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.

Authors:  Ramin Mehin; Bryn Jones; Qingan Zhu; Henry Broekhuyse
Journal:  Can J Surg       Date:  2009-06       Impact factor: 2.089

3.  A morphological study of anatomical plates for acetabular posterior column.

Authors:  Qinghua Liu; Kun Zhang; Yan Zhuang; Kai Tao; Yahui Fu
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-10-18       Impact factor: 2.924

4.  Biomechanical comparison of different stabilization constructs for unstable posterior wall fractures of acetabulum. A cadaveric study.

Authors:  Yuntong Zhang; Yang Tang; Panfeng Wang; Xue Zhao; Shuogui Xu; Chuncai Zhang
Journal:  PLoS One       Date:  2013-12-31       Impact factor: 3.240