Literature DB >> 7631624

Value and limitations of intravascular ultrasound imaging in characterizing coronary atherosclerotic plaque.

B J Kimura1, V Bhargava, A N DeMaria.   

Abstract

Intravascular ultrasound uses a high-frequency, miniaturized, ultrasound transducer positioned on the tip of a coronary catheter to provide detailed cross-sectional images of the coronary vessel wall. Unlike angiography, which details only luminal encroachment, this imaging technique has the unique potential to provide an image of the atherosclerotic plaque, characterize its composition, and assess stenosis severity. Lipid-filled "soft" plaque, dense fibrous "hard" plaque, calcification, and thrombosis have all been identified on intravascular ultrasound images. Individual lesion types have been associated with specific clinical ischemic syndromes and with different responses to catheter-based intervention. By means of analyzing tissue composition, intravascular ultrasound may permit identification of high-risk lesions that may eventually rupture and cause unstable coronary ischemic syndromes. This article reviews the current approaches to plaque characterization by two-dimensional intravascular ultrasound imaging and addresses clinical implications, technical limitations, and future promise of the technique.

Entities:  

Mesh:

Year:  1995        PMID: 7631624     DOI: 10.1016/0002-8703(95)90457-3

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  10 in total

1.  In vivo IVUS-based 3-D fluid-structure interaction models with cyclic bending and anisotropic vessel properties for human atherosclerotic coronary plaque mechanical analysis.

Authors:  Chun Yang; Richard G Bach; Jie Zheng; Issam Ei Naqa; Pamela K Woodard; Zhongzhao Teng; Kristen Billiar; Dalin Tang
Journal:  IEEE Trans Biomed Eng       Date:  2009-06-26       Impact factor: 4.538

2.  In vitro validation of the luminal measurement of a novel catheter based moulding technique.

Authors:  S C Eccleshall; P J Jordan; N P Buller; J N Townend
Journal:  Heart       Date:  1999-02       Impact factor: 5.994

3.  Highly Integrated Guidewire Ultrasound Imaging System-on-a-Chip.

Authors:  Jaemyung Lim; Coskun Tekes; Evren F Arkan; Ahmad Rezvanitabar; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE J Solid-State Circuits       Date:  2020-01-30       Impact factor: 5.013

4.  Clinical applications of intravascular ultrasound (IVUS): experience from an academic high volume centre of Northern Greece.

Authors:  A Mantziari; A Ziakas; G Stavropoulos; I H Styliadis
Journal:  Hippokratia       Date:  2011-01       Impact factor: 0.471

Review 5.  An Update on the Energy Sources and Catheter Technology for the Ablation of Atrial Fibrillation.

Authors:  Pawan K Arora; James C Hansen; Adam D Price; Josef Koblish; Boaz Avitall
Journal:  J Atr Fibrillation       Date:  2010-03-01

Review 6.  Intravascular ultrasound: principles and cerebrovascular applications.

Authors:  H Zacharatos; A E Hassan; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-04       Impact factor: 3.825

7.  Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging.

Authors:  Gokce Gurun; Coskun Tekes; Jaime Zahorian; Toby Xu; Sarp Satir; Mustafa Karaman; Jennifer Hasler; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-02       Impact factor: 2.725

8.  Risk factors of atherosclerotic tissue types in single-vessel and intermediate coronary lesions: a cross-sectional study.

Authors:  Xianjin Wang; Qun Chen; Yu Xu; Yanqing Wang; Yang Yang; Ming Gu; Haihua Xu; Yanfang Zhao
Journal:  Lipids Health Dis       Date:  2017-03-23       Impact factor: 3.876

9.  Hyperglycemia effect on coronary disease in patients with metabolic syndrome evaluated by intracoronary ultrasonography.

Authors:  Beatriz Dal Santo Francisco Bonamichi; Erika Bezerra Parente; Ana Carolina Noronha Campos; Adriano Namo Cury; João Eduardo Nunes Salles
Journal:  PLoS One       Date:  2017-02-10       Impact factor: 3.240

10.  Distribution of ultrasonic radiofrequency signal amplitude detects lipids in atherosclerotic plaque of coronary arteries: an ex-vivo study.

Authors:  Hisao Hara; Taro Tsunoda; Naohiko Nemoto; Itaru Yokouchi; Masaya Yamamoto; Tsuyoshi Ono; Masao Moroi; Makoto Suzuki; Kaoru Sugi; Masato Nakamura
Journal:  Cardiovasc Ultrasound       Date:  2008-05-09       Impact factor: 2.062

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.