Literature DB >> 7627315

Dioxin concentrations in the blood of workers at municipal waste incinerators.

A Schecter1, O Päpke, M Ball, A Lis, P Brandt-Rauf.   

Abstract

OBJECTIVES: Increased concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzo-furans (PCDFs) in pooled blood samples from workers at municipal waste incinerators have been reported. This study was undertaken to confirm these results in individual blood samples from potentially exposed and unexposed workers at municipal waste incinerators compared with matched unexposed controls and compared with concentrations in the slag and fly ash from the municipal waste incinerators.
METHODS: Concentrations of PCDDs and PCDFs were determined in the blood of 10 workers from an old municipal waste incinerator without adequate pollution controls, 11 workers from a newer incinerator with modern pollution controls, and 25 controls from the general population group matched for age (+/- 10 years), sex, and race, and in the slag and fly ash from the older incinerator.
RESULTS: Significant increases of certain PCDDs and PCDFs were found in the blood of the workers from the older incinerator compared with the controls as follows: octaCDD (1051 (438) v 637 (344), P < 0.001), hexaCDF (52.3 (28.7) v 30.2 (18.2), P < 0.01), heptaCDF (43.9 (30.4) v 22.7 (12.4), P < 0.001), total PCDDs (1262 (484) v 825 (454), P < 0.001), total PCDFs (133.0 (68.1) v 93.7 (36.7), P < 0.05), and total PCDD/Fs (1395 (537) v 918 (437), P < 0.001). The workers from the older incinerator with the greatest exposure were found to have the most significant increases of the blood PCDDs and PCDFs, and the pattern of increased PCDD and PCDF congeners in the blood corresponded to the pattern in the incinerator slag and ash. No significant differences were found between the blood concentrations of the workers at the newer incinerator and the controls.
CONCLUSION: Occupational exposure to slag and fly ash from municipal waste incinerators may increase the blood concentrations of PCDDs and PCDFs. Modern pollution control technology in new incinerators may be able to minimise potential exposure to slag and fly ash and thus the absorption of PCDDs and PCDFs from this source.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7627315      PMCID: PMC1128242          DOI: 10.1136/oem.52.6.385

Source DB:  PubMed          Journal:  Occup Environ Med        ISSN: 1351-0711            Impact factor:   4.402


  2 in total

1.  Dust control in measles wards, with a note on sulphadiazine prophylaxis.

Authors:  N D BEGG; E W SMELLIE; J WRIGHT
Journal:  Br Med J       Date:  1947-02-08

2.  Long-term chemical carcinogenesis experiments for identifying potential human cancer hazards: collective database of the National Cancer Institute and National Toxicology Program (1976-1991).

Authors:  J Huff; J Haseman
Journal:  Environ Health Perspect       Date:  1991-12       Impact factor: 9.031

  2 in total
  10 in total

1.  Morbidity among municipal waste incinerator workers: a cross-sectional study.

Authors:  Martine Hours; Lucie Anzivino-Viricel; Anne Maitre; Alain Perdrix; Yves Perrodin; Barbara Charbotel; Alain Bergeret
Journal:  Int Arch Occup Environ Health       Date:  2003-05-23       Impact factor: 3.015

2.  Does long term residency near industry have an impact on the body burden of polychlorinated dibenzo-p-dioxins, furans, and polychlorinated biphenyls in older women?

Authors:  T Pless-Mulloli; R Edwards; D Howel; R Wood; O Paepke; T Herrmann
Journal:  Occup Environ Med       Date:  2005-12       Impact factor: 4.402

3.  DIOXINS AND FURANS; AND HOSPITAL WASTE INCINERATION.

Authors:  L K Verma; J N Srivastava
Journal:  Med J Armed Forces India       Date:  2017-06-08

4.  Polychlorinated dibenzo-p-dioxin and dibenzofuran concentrations in the serum samples of workers at continuously burning municipal waste incinerators in Japan.

Authors:  S Kumagai; S Koda; T Miyakita; H Yamaguchi; K Katagi; N Yasuda
Journal:  Occup Environ Med       Date:  2000-03       Impact factor: 4.402

5.  Polychlorinated dibenzo-p-dioxin and dibenzofuran concentrations in serum samples of workers at intermittently burning municipal waste incinerators in Japan.

Authors:  S Kumagai; S Koda; T Miyakita; M Ueno
Journal:  Occup Environ Med       Date:  2002-06       Impact factor: 4.402

6.  An integrated approach for identification of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) pollutant sources based on human blood contents.

Authors:  Yu-Cheng Chen; Perng-Jy Tsai; Lin-Chi Wang; Minliang Shih; Wen-Jhy Lee
Journal:  Environ Sci Pollut Res Int       Date:  2009-05-21       Impact factor: 4.223

7.  State of the art and advances in the impact assessment of dioxins and dioxin-like compounds.

Authors:  Marco Schiavon; Vincenzo Torretta; Elena Cristina Rada; Marco Ragazzi
Journal:  Environ Monit Assess       Date:  2015-12-24       Impact factor: 2.513

8.  Melting and incineration plants of municipal waste. Chemical and biochemical diagnosis of thermal processing samples (emission, residues).

Authors:  Peter A Behnisch; Kazunori Hosoe; Ken Shiozaki; Tetsuya Kiryu; Kenichi Komatsu; Karl-Werner Schramm; Shin-ichi Sakai
Journal:  Environ Sci Pollut Res Int       Date:  2002       Impact factor: 4.223

9.  Isomer pattern and elimination of dioxins in workers exposed at a municipal waste incineration plant.

Authors:  Kenya Yamamoto; Mitsuhiro Kudo; Heihachiro Arito; Yasutaka Ogawa; Tsutomu Takata
Journal:  Ind Health       Date:  2015-06-26       Impact factor: 2.179

10.  A cross-sectional analysis of dioxins and health effects in municipal and private waste incinerator workers in Japan.

Authors:  Kenya Yamamoto; Mitsuhiro Kudo; Heihachiro Arito; Yasutaka Ogawa; Tsutomu Takata
Journal:  Ind Health       Date:  2015-07-23       Impact factor: 2.179

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.