Literature DB >> 7626358

Comparison of three dimensional echocardiographic findings with anatomical specimens of various congenitally malformed hearts.

M Vogel1, S Y Ho, R H Anderson.   

Abstract

OBJECTIVE: To compare the reconstructions obtained by three dimensional echocardiography with the anatomical specimens used to generate the echocardiograms.
DESIGN: The heart specimens were immersed in a water bath and imaged with a 5 MHz echocardiographic transducer mounted into a scan frame which allowed the transducer to travel a total distance of 4.4 cm in steps of 0.25 mm. The transducer records a tomographic slice at each incremental level thus producing 176 parallel slices of the heart to form the dataset. Reconstruction of the anatomical structures of the heart in a three dimensional format is achieved by means of different grey scales. MATERIALS: 72 specimens of either normal or various congenitally malformed hearts.
RESULTS: Good quality echocardiographic pictures were obtained, permitting three dimensional reconstructions in each heart. The cardiac chambers and valves could be displayed in a three dimensional format which accurately displayed the internal anatomy of the specimens. No artefacts, such as spurious septal defects, were produced in specimens with intact septums. The atrioventricular valvar leaflets, however, appeared thicker in the images than they were in the specimens.
CONCLUSIONS: Three dimensional echocardiography accurately displays the anatomy of normal and congenitally malformed hearts.

Entities:  

Mesh:

Year:  1995        PMID: 7626358      PMCID: PMC483921          DOI: 10.1136/hrt.73.6.566

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  6 in total

1.  Morphologic-echocardiographic correlates of Ebstein's malformation.

Authors:  P G Rusconi; J R Zuberbuhler; R H Anderson; M L Rigby
Journal:  Eur Heart J       Date:  1991-07       Impact factor: 29.983

2.  Echocardiographic criteria for Ebstein's anomaly of tricuspid valve.

Authors:  W J Gussenhoven; S E Spitaels; N Bom; A E Becker
Journal:  Br Heart J       Date:  1980-01

3.  Ventricular septal defect and subaortic stenosis: an analysis of 41 patients.

Authors:  M Vogel; R M Freedom; A Brand; G A Trusler; W G Williams; R D Rowe
Journal:  Am J Cardiol       Date:  1983-12-01       Impact factor: 2.778

4.  Morphologic spectrum of Ebstein's anomaly of the heart: a review.

Authors:  K R Anderson; J R Zuberbuhler; R H Anderson; A E Becker; J T Lie
Journal:  Mayo Clin Proc       Date:  1979-03       Impact factor: 7.616

5.  Dynamic three-dimensional echocardiography with a computed tomography imaging probe: initial clinical experience with transthoracic application in infants and children with congenital heart defects.

Authors:  M Vogel; S Lösch
Journal:  Br Heart J       Date:  1994-05

6.  Membranous supravalvular mitral stenosis: a treatable form of congenital heart disease.

Authors:  I D Sullivan; P J Robinson; M de Leval; T P Graham
Journal:  J Am Coll Cardiol       Date:  1986-07       Impact factor: 24.094

  6 in total
  2 in total

1.  Three dimensional echocardiography in congenital heart defects.

Authors:  Girish S Shirali
Journal:  Ann Pediatr Cardiol       Date:  2008-01

2.  Three-dimensional echocardiography of ventricular septal defects.

Authors:  M Hoch; U Roemer; R Kozlik-Feldmann; A Fuchs; H Netz
Journal:  Images Paediatr Cardiol       Date:  2002-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.