Literature DB >> 7621929

Influence of handedness on motor unit discharge properties and force tremor.

J G Semmler1, M A Nordstrom.   

Abstract

Discharge properties of motor units (MUs) in the first dorsal interosseous muscle (FDI) were studied in the dominant and non-dominant hands of six right-handed (RH) and six left-handed (LH) individuals. MU discharge rates and variability were similar in each hand in RH (186 MUs) and LH (160 MUs) subjects. MU synchronization was less prominent in the dominant hand of RH subjects, with 51% (45/88) of cross-correlograms of MU discharge having significant central peaks, compared with 81% (90/111) for the non-dominant hand. The strength of MU synchronization (expressed as the frequency of extra synchronous discharges above chance) was weaker in the dominant hand of right-handers (0.23 +/- 0.03 s-1 vs 0.39 +/- 0.03 s-1), and synchronous peaks from that hand were slightly broader. Four of six RH subjects had significant differences in synchronization between hands (weaker in dominant hand). In contrast, left-handers had similar incidence (80 vs 82%, n = 161) and strength (0.41 +/- 0.03 s-1 vs 0.37 +/- 0.03 s-1) of MU synchrony in dominant and non-dominant hands. No LH subject had a significant difference in synchronization between hands. Force tremor was quantified in each hand in the same subjects during isometric abduction of FDI at 0.5 N and 3.5 N, and directly correlated with the extent of MU synchronization in the muscle. Tremor root mean square amplitude was similar in dominant and non-dominant hands. Power spectral analysis of the tremor force revealed that the peak frequency in the power spectrum was not influenced by handedness, but power at the peak frequency was higher in the non-dominant hand of RH subjects. Correlations between MU discharge variability and synchrony with measures of tremor amplitude were weak. The reduced MU synchronization in the dominant hand of right-handers may reflect a more restricted distribution of direct projections from motor cortical neurons within the FDI motoneuron pool, or reduced excitability of the cortical neurons during the task. These differences in MU synchronization, however, had an insignificant influence on the magnitude of physiological tremor in the FDI.

Entities:  

Mesh:

Year:  1995        PMID: 7621929     DOI: 10.1007/bf00229861

Source DB:  PubMed          Journal:  Exp Brain Res        ISSN: 0014-4819            Impact factor:   1.972


  40 in total

1.  Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor.

Authors:  R J Elble; J E Randall
Journal:  J Neurophysiol       Date:  1976-03       Impact factor: 2.714

2.  Reduced control of motor output in a human hand muscle of elderly subjects during submaximal contractions.

Authors:  M E Galganski; A J Fuglevand; R M Enoka
Journal:  J Neurophysiol       Date:  1993-06       Impact factor: 2.714

3.  A comparison of the mechanical properties of the first dorsal interosseous in the dominant and non-dominant hand.

Authors:  M Tanaka; M J McDonagh; C T Davies
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1984

4.  Mechanistic components of normal hand tremor.

Authors:  R J Elble; J E Randall
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1978-01

5.  Cumulative sum technique and its application to the analysis of peristimulus time histograms.

Authors:  P H Ellaway
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1978-08

6.  Mechanical and neural feedback factors in postural hand tremor of normal subjects.

Authors:  R N Stiles
Journal:  J Neurophysiol       Date:  1980-07       Impact factor: 2.714

7.  Short-term synchronization of intercostal motoneurone activity.

Authors:  T A Sears; D Stagg
Journal:  J Physiol       Date:  1976-12       Impact factor: 5.182

8.  Mechanical implications of paired motor unit discharges in pathological and voluntary tremor.

Authors:  J M Elek; R Dengler; A Konstanzer; S Hesse; W Wolf
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1991-08

9.  Corticospinal terminations in two new-world primates: further evidence that corticomotoneuronal connections provide part of the neural substrate for manual dexterity.

Authors:  G A Bortoff; P L Strick
Journal:  J Neurosci       Date:  1993-12       Impact factor: 6.167

10.  Myo-electric signals from two extrinsic hand muscles and force tremor during isometric handgrip.

Authors:  W N Löscher; E Gallasch
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1993
View more
  19 in total

1.  Common synaptic input to the human hypoglossal motor nucleus.

Authors:  Christopher M Laine; E Fiona Bailey
Journal:  J Neurophysiol       Date:  2010-11-17       Impact factor: 2.714

2.  Synchronization of motor unit firings: an epiphenomenon of firing rate characteristics not common inputs.

Authors:  Joshua C Kline; Carlo J De Luca
Journal:  J Neurophysiol       Date:  2015-10-21       Impact factor: 2.714

3.  A simulation study to examine the effect of common motoneuron inputs on correlated patterns of motor unit discharge.

Authors:  Madeleine M Lowery; Zeynep Erim
Journal:  J Comput Neurosci       Date:  2005-10       Impact factor: 1.621

4.  Exertion dependent alternations in force fluctuation and limb acceleration during sustained fatiguing contraction.

Authors:  Chien-Ting Huang; Ing-Shiou Hwang; Chien-Chun Huang; Ming-Shing Young
Journal:  Eur J Appl Physiol       Date:  2006-05-10       Impact factor: 3.078

5.  How computational technique and spike train properties affect coherence detection.

Authors:  K Terry; L Griffin
Journal:  J Neurosci Methods       Date:  2007-09-26       Impact factor: 2.390

6.  Motor unit firing variability and synchronization during short-term light-load training in older adults.

Authors:  L Griffin; P E Painter; A Wadhwa; W W Spirduso
Journal:  Exp Brain Res       Date:  2009-07-04       Impact factor: 1.972

7.  Common synaptic input across motor nuclei supplying intrinsic muscles involved in the precision grip.

Authors:  Tara L McIsaac; Andrew J Fuglevand
Journal:  Exp Brain Res       Date:  2008-05-28       Impact factor: 1.972

8.  Motor unit recruitment and proprioceptive feedback decrease the common drive.

Authors:  Carlo J De Luca; Jose A Gonzalez-Cueto; Paolo Bonato; Alexander Adam
Journal:  J Neurophysiol       Date:  2008-06-18       Impact factor: 2.714

9.  10 Hz periodic component influences lower frequency component of the physiological tremor at low force levels.

Authors:  Hiroshi Endo; Koichi Kawahara
Journal:  Eur J Appl Physiol       Date:  2011-03-12       Impact factor: 3.078

10.  Fatigue related changes in electromyographic coherence between synergistic hand muscles.

Authors:  Shashikala Kattla; Madeleine M Lowery
Journal:  Exp Brain Res       Date:  2009-12-12       Impact factor: 1.972

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.