Literature DB >> 7621644

Beat-to-beat agreement of non-invasive finger artery and invasive radial artery blood pressure in hypertensive patients taking cardiovascular medication.

A Lindqvist1.   

Abstract

The aim of this study was to investigate and quantify the agreement between simultaneous and ipsilateral non-invasive finger artery blood pressure (Finapres) and intra-arterial radial blood pressure among 13 volunteer hypertensive patients, aged 36-71 years and taking cardiovascular medication, during steady-state fluctuation of arterial blood pressure and during an increase in blood pressure induced by static exercise. Eight patients were being treated with beta-blocking agents, eight with calcium antagonists, four with angiotensin-converting enzyme inhibitors, four with diuretics and one with prazosin in combination therapy. Their auscultatory brachial artery blood pressures ranged in systole from 142 to 206 mmHg and in diastole from 88 to 120 mmHg during the treatment. The mean systolic finger artery blood pressure deviated by -14 +/- 5 mmHg (P = 0.02, mean value +/- SEM) and the diastolic finger artery blood pressure deviated by 0.6 +/- 3 mmHg (P = 0.70) from the corresponding radial artery pressure. The maximal beat-to-beat difference between systolic and diastolic finger and radial artery pressure, respectively, showed that a range of less than 10 mmHg in the steady state after individual adjustment for bias. In general, neither systolic nor diastolic differences between the methods exceeded the limits of +/- 10 mmHg, and the bias did not significantly increase (P > or = 0.12) during a 10-mmHg increase in arterial blood pressure caused by static exercise. Among three subjects, an increase in bias and poorer agreement was associated with atrial fibrillation and steplike changes in the Finapres output after autocalibration. The results support usage of the Finapres technique to measure beat-to-beat changes of peripheral arterial blood pressure in hypertensive patients taking cardiovascular medication, with a feasible agreement with beat-to-beat radial artery blood pressure.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7621644     DOI: 10.1111/j.1475-097x.1995.tb00513.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  4 in total

1.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

2.  Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure.

Authors:  I Constant; D Laude; J L Elghozi; I Murat
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

3.  Tissue-informative mechanism for wearable non-invasive continuous blood pressure monitoring.

Authors:  Sung Hun Woo; Yun Young Choi; Dae Jung Kim; Franklin Bien; Jae Joon Kim
Journal:  Sci Rep       Date:  2014-10-21       Impact factor: 4.379

4.  Exercise in Water Provides Better Cardiac Energy Efficiency Than on Land.

Authors:  Marina Fukuie; Daisuke Hoshi; Tatsuya Hashitomi; Koichi Watanabe; Takashi Tarumi; Jun Sugawara
Journal:  Front Cardiovasc Med       Date:  2021-12-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.