Literature DB >> 7609534

Bioelectric impedance detects fluid retention in patients undergoing cardiopulmonary bypass.

J Gonzalez1, T Morrissey, T Byrne, R Rizzo, D Wilmore.   

Abstract

Excessive fluid accumulation is associated with increased morbidity and prolonged convalescence after cardiopulmonary bypass. However, water fluctuations are difficult to assess solely on the basis of changes in body weight and fluid balance. Bioelectric impedance analysis is a simple, rapid, noninvasive bedside technique that measures the resistance of the body to a weak alternating current (50 kHz). The change in resistance is inversely proportional to the change in total body water. To investigate the relationship between body weight, fluid balance, and resistance, 18 patients who had cardiopulmonary bypass (9 men, 9 women, aged 61 +/- 3 years, weighing 80 +/- 4 kg, with ejection fraction 54% +/- 3% and bypass time 113 +/- 8 minutes [mean plus or minus standard error of the mean]) were followed up for 7 postoperative days. Body weight, fluid balance, and whole body and regional resistance were determined at 24-hour intervals. In the immediate postoperative period, fluid retention was accurately detected by simultaneous measurements of weight gain and decreased resistance (p < 0.001). Both measurements detected the initiation of diuresis by postoperative day 2 (p < 0.01). Whole body resistance returned to baseline values by day 7 (p > 0.05), and body weight returned to baseline on day 4 (p > 0.05). Change in weight and change in whole body resistance were highly correlated with cumulative fluid balance (r = 0.84, p < 0.001, and r = -0.81, p < 0.001, respectively), and these two measures were also related to each other throughout the study (r = -0.89, p < 0.001). The initial change in resistance was the best measurement associated with postoperative outcome (p < or = 0.01). The data suggest that the measurement of electric resistance across the body can accurately detect acute changes in total body water and in fluid redistribution through the body. However, determining the relative day-to-day change in whole body resistance seems more appropriate than calculating absolute fluid changes over time. Bioelectric impedance offers a simple, rapid, noninvasive method to monitor serial changes in total body water. This technique can be useful in situations in which rapid alterations in water compartments occur, and it may be useful in predicting outcome after cardiopulmonary bypass.

Entities:  

Mesh:

Year:  1995        PMID: 7609534     DOI: 10.1016/S0022-5223(05)80016-9

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  3 in total

1.  Bioelectrical impedance analysis predicts outcome in patients with suspected bacteremia.

Authors:  A Schwenk; L C Ward; M Elia; G M Scott
Journal:  Infection       Date:  1998 Sep-Oct       Impact factor: 3.553

2.  Diagnosing capillary leak in critically ill patients: development of an innovative scoring instrument for non-invasive detection.

Authors:  Jakob Wollborn; Lars O Hassenzahl; Daniel Reker; Hans Felix Staehle; Anne Marie Omlor; Wolfgang Baar; Kai B Kaufmann; Felix Ulbrich; Christian Wunder; Stefan Utzolino; Hartmut Buerkle; Johannes Kalbhenn; Sebastian Heinrich; Ulrich Goebel
Journal:  Ann Intensive Care       Date:  2021-12-15       Impact factor: 6.925

3.  Perioperative fluid dynamics evaluated by bioelectrical impedance analysis predict infectious surgical complications after esophagectomy.

Authors:  Shuichiro Oya; Hiroharu Yamashita; Ryohei Iwata; Koichiro Kawasaki; Asami Tanabe; Koichi Yagi; Susumu Aikou; Yasuyuki Seto
Journal:  BMC Surg       Date:  2019-12-02       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.