Literature DB >> 7609368

[Silicone one piece intraocular implant and anterior capsule fibrosis].

C Auer1, M Gonvers.   

Abstract

BACKGROUND: Foldable plate haptic silicone intraocular lenses (IOLs) were surmised to produce greater anterior capsule fibrosis than poly(methyl metacrylate) (PMMA) intraocular lenses.
MATERIAL AND METHODS: A retrospective study of 34 eyes was carried out 12 to 15 months after phacoemulsification. All surgical procedures were performed by the same surgeon (M.G.) using two different techniques: 17 eyes were operated on through a temporal clear-cornea incison and implanted with a foldable plate haptic silicone IOL (STAAR AA4203); 17 eyes were operated on through a superior sclerocorneal incision and received a PMMA IOL (Kabi Pharmacia 809P). Secondary opacification of the anterior capsule was compared between the two groups.
RESULTS: Seventy percent of eyes (12/17) with plate haptic silicone IOL had moderate or important anterior capsule fibrosis or shrinkage. Only 18% of eyes (3/17) with PMMA IOL presented with this complication. However, posterior capsule opacification was almost similar in both groups.
CONCLUSION: Foldable plate haptic silicone IOLs seem to produce a more important anterior capsule fibrosis or shrinkage than PMMA IOL one year after phacoemulsification and saccular implantation. Although etiology is unknown, either huge contact between IOL and anterior capsule, or lack of contact between anterior and posterior capsules are hypotheses advanced. Posterior capsule opacification is similar in the two groups.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7609368     DOI: 10.1055/s-2008-1035444

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  3 in total

1.  Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

Authors:  D J Apple
Journal:  Trans Am Ophthalmol Soc       Date:  2000

2.  Effect of the hydrophilicity of acrylic intraocular lens material and haptic angulation on anterior capsule opacification.

Authors:  Lorenz Vock; Michael Georgopoulos; Thomas Neumayer; Wolf Buehl; Oliver Findl
Journal:  Br J Ophthalmol       Date:  2006-11-15       Impact factor: 4.638

3.  Microincisional cataract surgery and Thinoptx rollable intraocular lens implantation.

Authors:  Necdet Cinhüseyinoglu; Lider Celik; Aylin Yaman; Gül Arikan; Tülin Kaynak; Süleyman Kaynak
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-11-29       Impact factor: 3.117

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.