Literature DB >> 759880

Serial assessment of doxorubicin cardiotoxicity with quantitative radionuclide angiocardiography.

J Alexander, N Dainiak, H J Berger, L Goldman, D Johnstone, L Reduto, T Duffy, P Schwartz, A Gottschalk, B L Zaret.   

Abstract

We measured cardiac performance sequentially, using quantitative radionuclide angiocardiography to estimate left ventricular ejection fraction in 55 patients receiving doxorubicin for treatment of cancer. With final doxorubicin dosages greater than 350 mg per square meter, the lowest ejection fraction measured was significantly less than the initial determination. Five patients had severe cardiotoxicity (congestive heart failure). All had an ejection fraction of less than 30 per cent at the time of heart failure, and demonstrated moderate cardiotoxicity (a decline in ejection fraction by at least 15 per cent to a final value of less than 45 per cent) before clinical manifestations. Six patients with moderate toxicity in whom doxorubicin was discontinued did not have heart failure or a further decline in ejection fraction during the follow-up period. Moderate toxicity was continued, but mild toxicity (decline of ejection fraction by greater than 10 per cent, noted in 11 patients) was not well predicted. The assessment of radionuclide left ventricular ejection fraction during doxorubicin therapy may make it possible to avoid congestive heart failure.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 759880     DOI: 10.1056/NEJM197902083000603

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  91 in total

Review 1.  Cardiotoxicity of doxorubicin and other anthracycline derivatives.

Authors:  D Jain
Journal:  J Nucl Cardiol       Date:  2000 Jan-Feb       Impact factor: 5.952

2.  Diastolic or systolic left and right ventricular impairment at moderate doses of anthracycline? A 1-year follow-up study of women.

Authors:  Y Cottin; C Touzery; B Coudert; S Richebourg; M Cohen; M Toubeau; P Louis; J E Wolf; F Brunotte
Journal:  Eur J Nucl Med       Date:  1996-05

3.  Imaging and chemotherapy cardiotoxicity: A long-playing story still seeking precision and improved outcomes/management data.

Authors:  William A Van Decker
Journal:  J Nucl Cardiol       Date:  2015-09-04       Impact factor: 5.952

Review 4.  Monitoring chemotherapy-induced cardiotoxicity: role of cardiac nuclear imaging.

Authors:  Gurusher Singh Panjrath; Diwakar Jain
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

5.  A randomized multicenter trial of cyclophosphamide, Novantrone and 5-fluorouracil (CNF) versus cyclophosphamide, Adriamycin and 5-fluorouracil (CAF) in patients with metastatic breast cancer.

Authors:  J M Bennett; P Byrne; A Desai; C White; R DeConti; C Vogel; E Krementz; F Muggia; J Doroshow; D Plotkin
Journal:  Invest New Drugs       Date:  1985       Impact factor: 3.850

6.  Mitoxantrone: an overview of safety and toxicity.

Authors:  L E Posner; G Dukart; J Goldberg; T Bernstein; K Cartwright
Journal:  Invest New Drugs       Date:  1985       Impact factor: 3.850

7.  Early detection of doxorubicin cardiotoxicity by M-mode echocardiography.

Authors:  W Markiewicz; E Robinson; B Peled; S Kaufman; A Carter
Journal:  Cancer Chemother Pharmacol       Date:  1980       Impact factor: 3.333

8.  The Cardiotoxic Mechanism of Doxorubicin (DOX) and Pegylated Liposomal DOX in Mice Bearing C-26 Colon Carcinoma: a Study Focused on microRNA Role for Toxicity Assessment of New Formulations.

Authors:  Kamal Razavi-Azarkhiavi; Mahmoud Reza Jaafari; Khalil Abnous; Bibi Marjan Razavi; Amir Hossein Jafarian; Faezeh Vahdati Hassani; Kobra Shirani; Gholamreza Karimi
Journal:  Pharm Res       Date:  2017-05-30       Impact factor: 4.200

9.  Assessing the Cardiac Toxicity of Chemotherapeutic Agents: Role of Echocardiography.

Authors:  Timothy C Tan; Marielle Scherrer-Crosbie
Journal:  Curr Cardiovasc Imaging Rep       Date:  2012-12-01

10.  Early detection of doxorubicin and daunorubicin cardiotoxicity by echocardiography: diastolic versus systolic parameters.

Authors:  K Schmitt; G Tulzer; M Merl; G Aichhorn; A Grillenberger; G Wiesinger; G Hofstadler
Journal:  Eur J Pediatr       Date:  1995-03       Impact factor: 3.183

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.