Literature DB >> 7596268

Pulses with fixed magnitude and variable phase response profiles.

S Pickup1, X Ding.   

Abstract

The Shinnar-Le Roux (SLR) method of pulse envelope design provides for the generation of nearly arbitrary magnitude response profiles with such great efficiency that the pulse envelopes may often be calculated at the time of sequence initiation. A significant limitation of the method is that it provides only limited control of the phase of the response profile. In the current manuscript it is demonstrated that the phase of the response profile can be modulated without affecting the magnitude profile by replacement of some of the roots of the SLR polynomials with one over their complex conjugate. This method allows interactive tailoring of the phase profile to the user's needs. Although the method does not allow for the optimization of arbitrary phase profiles, a variety of pulses, which are of general utility, have been generated. Some of these pulses and their response profiles are presented.

Mesh:

Year:  1995        PMID: 7596268     DOI: 10.1002/mrm.1910330509

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Multiband RF pulses with improved performance via convex optimization.

Authors:  Hong Shang; Peder E Z Larson; Adam Kerr; Galen Reed; Subramaniam Sukumar; Adam Elkhaled; Jeremy W Gordon; Michael A Ohliger; John M Pauly; Michael Lustig; Daniel B Vigneron
Journal:  J Magn Reson       Date:  2015-12-14       Impact factor: 2.229

2.  Near-contiguous spin echo imaging using matched-phase RF and its application in velocity-selective arterial spin labeling.

Authors:  Zungho Zun; Brian A Hargreaves; John Pauly; Greg Zaharchuk
Journal:  Magn Reson Med       Date:  2013-07-15       Impact factor: 4.668

3.  Root-flipped multiband refocusing pulses.

Authors:  Anuj Sharma; Michael Lustig; William A Grissom
Journal:  Magn Reson Med       Date:  2015-02-22       Impact factor: 4.668

4.  Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging.

Authors:  Jun Ma; Carrie Wismans; Zhipeng Cao; Dennis W J Klomp; Jannie P Wijnen; William A Grissom
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

5.  Which pulse sequence is optimal for myo-inositol detection at 3T?

Authors:  Ileana Hancu
Journal:  NMR Biomed       Date:  2009-05       Impact factor: 4.044