Literature DB >> 7594994

Absorbable sutures in tendon repair. A comparison of PDS with prolene in rabbit tendon repair.

E S O'Broin, M J Earley, H Smyth, A C Hooper.   

Abstract

The risks of foreign implantation may be avoided in tendon repair by the use of absorbable sutures, for example polydioxanone. In this study, the in vivo tensile strength half-life of 4/0 polydioxanone was found to be approximately 4 weeks. Using a rabbit model, we compared polydioxanone tendon repairs with polypropylene tendon repairs. Unilateral flexor digitorum longus repairs were performed on 46 rabbits using either polydioxanone or polypropylene. Tendons were harvested at 3 days, 2 weeks and 4 weeks and the tensile breaking strengths were obtained. 30 intact rabbit flexor digitorum longus tendons and 20 freshly repaired tendons were also tested. By 4 weeks, the repair strength had increased eight-fold from approximately 20 N to 166 N. The sutures made little contribution to the overall strength of a 4-week-old repair. There was no significant difference between polydioxanone and polypropylene repairs at any stage. These results show that polydioxanone repairs were as strong as polypropylene during the first critical weeks of tendon healing.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7594994     DOI: 10.1016/s0266-7681(05)80164-0

Source DB:  PubMed          Journal:  J Hand Surg Br        ISSN: 0266-7681


  10 in total

1.  Practice patterns in flexor tendon repair.

Authors:  C Healy; K J Mulhall; D J Bouchier-Hayes; B Kneafsey
Journal:  Ir J Med Sci       Date:  2007-03       Impact factor: 1.568

2.  Flexor tenorrhaphy using absorbable suture materials.

Authors:  Hyung Joo Kang; Dong Chul Lee; Jin Soo Kim; Sae Hwi Ki; Si Young Roh; Jae Won Yang
Journal:  Arch Plast Surg       Date:  2012-07-13

Review 3.  Barbed Sutures and Tendon Repair-a Review.

Authors:  Ajul Shah; Megan Rowlands; Alexander Au
Journal:  Hand (N Y)       Date:  2015-03

4.  [Suture techniques and material in surgery of flexor tendons].

Authors:  T Pillukat; R Fuhrmann; J Windolf; J van Schoonhoven
Journal:  Chirurg       Date:  2017-03       Impact factor: 0.955

5.  In vitro evaluation of the response of human tendon-derived stromal cells to a novel electrospun suture for tendon repair.

Authors:  Andrey Nezhentsev; Roxanna E Abhari; Mathew J Baldwin; Jolet Y Mimpen; Edyta Augustyniak; Mark Isaacs; Pierre-Alexis Mouthuy; Andrew J Carr; Sarah J B Snelling
Journal:  Transl Sports Med       Date:  2021-03-15

6.  Bioabsorbable poly-L/D-lactide (PLDLA) 96/4 triple-stranded bound suture in the modified Kessler repair: an ex vivo static and cyclic tensile testing study in a porcine extensor tendon model.

Authors:  Anna-Kaarina Viinikainen; Harry Göransson; Katja Huovinen; Minna Kellomäki; Pertti Törmälä; Pentti Rokkanen
Journal:  J Mater Sci Mater Med       Date:  2009-05-13       Impact factor: 3.896

7.  Flexor tendon healing within the tendon sheath using bioabsorbable poly-L/D-lactide 96/4 suture. A histological in vivo study with rabbits.

Authors:  Anna Viinikainen; Harry Göransson; Hanna-Stina Taskinen; Matias Röyttä; Minna Kellomäki; Pertti Törmälä; Pentti Rokkanen
Journal:  J Mater Sci Mater Med       Date:  2014-01-30       Impact factor: 3.896

Review 8.  Natural, synthetic and commercially-available biopolymers used to regenerate tendons and ligaments.

Authors:  Behzad Shiroud Heidari; Rui Ruan; Ebrahim Vahabli; Peilin Chen; Elena M De-Juan-Pardo; Minghao Zheng; Barry Doyle
Journal:  Bioact Mater       Date:  2022-04-13

9.  IMMEDIATE AND LATE EFFECT OF SUTURES IN EXTRASYNOVIAL TENDONS: BIOMECHANICAL STUDY IN RATS.

Authors:  Trajano Sardenberg; Sérgio Swain Muller; Luciana Zauhy Garms; Francini Belluci Miduati
Journal:  Rev Bras Ortop       Date:  2015-12-08

Review 10.  Exceptional laceration of flexor digitorum tendons proximal to a severe palmar hand wound: a case report with literature review.

Authors:  Badr Ennaciri; Mustapha Mahfoud; Ahmed El Bardouni; Mohamed Saleh Berrada
Journal:  Pan Afr Med J       Date:  2015-11-20
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.