| Literature DB >> 7593079 |
N D Weiss1, L Gordon, T Bloom, Y So, D M Rempel.
Abstract
Increased carpal-tunnel pressure has been implicated in the pathophysiology of carpal tunnel syndrome, but it is not known whether splints that immobilize the wrist in a functional position of extension minimize carpal tunnel pressure. To determine the position of the wrist that results in the lowest carpal-tunnel pressure, twenty control subjects and four patients who had carpal tunnel syndrome were evaluated with use of a new, dynamic method that continuously measures carpal tunnel pressure throughout the range of motion of the wrist. The pressure was measured by means of a pressure transducer connected to a flexible catheter that had been inserted into the carpal canal. The position of the wrist was measured simultaneously with use of a two-axis electrogoniometer. Aided by a computer monitor that displayed a moving line of real-time carpal-tunnel pressure, each subject was instructed to move the wrist throughout the range of motion and to adjust it to the position that corresponded to the lowest carpal-tunnel pressure. For the control subjects, the lowest carpal-tunnel pressure averaged 8 +/- 4 millimeters of mercury (1.07 +/- 0.53 kilopascals), and the average position of the wrist associated with the lowest pressure was 2 +/- 9 degrees of extension and 2 +/- 6 degrees of ulnar deviation.(ABSTRACT TRUNCATED AT 250 WORDS)Entities:
Mesh:
Year: 1995 PMID: 7593079 DOI: 10.2106/00004623-199511000-00008
Source DB: PubMed Journal: J Bone Joint Surg Am ISSN: 0021-9355 Impact factor: 5.284