Literature DB >> 7593074

Tissue response to particulate polymethylmethacrylate in mice with various immune deficiencies.

W Jiranek1, M Jasty, J T Wang, C Bragdon, H Wolfe, M Goldberg, W Harris.   

Abstract

We examined the tissue response to subcutaneous injections of particulate polymethylmethacrylate powder in fully immunocompetent C3Hf/Sed mice as well as three strains of mice with different levels of lymphocyte dysfunction. Five weeks after the injection, we found clearly demarcated granulomas. Histological and immunohistochemical studies showed that these granulomas were similar among all strains, with either paucity or absence of lymphoid cells. In situ hybridization with use of complementary RNA probes indicated that macrophages were synthesizing interleukin-1 beta messenger RNA (mRNA), a marker of macrophage activation, and a cytokine implicated in pathological bone resorption. We concluded that, in mice, there is a lymphocyte-independent pathway of macrophage activation in response to particulate polymethylmethacrylate. This suggests that the foreign-body response to particulate orthopaedic biomaterials is macrophage-initiated and maintained and that lymphocytes are not essential to this response, although they may modulate it.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7593074     DOI: 10.2106/00004623-199511000-00003

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  7 in total

Review 1.  [Wear particles: key to aseptic prosthetic loosening?].

Authors:  M Otto; J Kriegsmann; T Gehrke; S Bertz
Journal:  Pathologe       Date:  2006-11       Impact factor: 1.011

2.  Innate immune reactions in septic and aseptic osteolysis around hip implants.

Authors:  Jukka Pajarinen; Eemeli Jamsen; Yrjo T Konttinen; Stuart B Goodman
Journal:  J Long Term Eff Med Implants       Date:  2014

3.  Do tissues from THA revision of highly crosslinked UHMWPE liners contain wear debris and associated inflammation?

Authors:  Ryan M Baxter; Theresa A Freeman; Steven M Kurtz; Marla J Steinbeck
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

4.  Interaction of Materials and Biology in Total Joint Replacement - Successes, Challenges and Future Directions.

Authors:  J Pajarinen; T-H Lin; T Sato; Z Yao; S B Goodman
Journal:  J Mater Chem B       Date:  2014-11-07       Impact factor: 6.331

5.  The central role of wear debris in periprosthetic osteolysis.

Authors:  P Edward Purdue; Panagiotis Koulouvaris; Bryan J Nestor; Thomas P Sculco
Journal:  HSS J       Date:  2006-09

6.  Perivascular and diffuse lymphocytic inflammation are not specific for failed metal-on-metal hip implants.

Authors:  Takaaki Fujishiro; Dirk Jan F Moojen; Naomi Kobayashi; Wouter J A Dhert; Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2010-10-29       Impact factor: 4.176

7.  The pathobiology and pathology of aseptic implant failure.

Authors:  N A Athanasou
Journal:  Bone Joint Res       Date:  2016-05       Impact factor: 5.853

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.