Literature DB >> 7591026

State of the market. A review of ambulatory blood pressure monitoring devices.

E O'Brien1, N Atkins, J Staessen.   

Abstract

The introduction of 24-hour ambulatory blood pressure measurement into clinical practice created a large market for ambulatory blood pressure measurement devices. Forty-three such devices from 31 manufacturers or suppliers are now available to satisfy a market demand that is likely to increase. The aim of this article is to identify the devices available and then to examine critically any validation studies assessing accuracy and performance. Of the 43 devices available 18 have been validated according to the protocols of the Association for the Advancement of Medical Instrumentation (AAMI) or the British Hypertension Society (BHS) in 25 reported studies. In 9 of these studies the protocol was not adhered to, and the results, which are therefore questionable, are noted but not considered further. Fourteen devices were evaluated according to the accuracy criteria of both protocols, and of these 9 fulfilled the requirements. From this review of 43 devices on the market it may be concluded that, at the time of writing, there is published evidence for only 9 devices meeting the generally accepted AAMI and BHS criteria for accuracy and performance; these are the A&D TM-2420 models 6 and 7 and TM-2421, CH-Druck, Nissei ABPM DS-240, Profilomat, QuietTrak, and SpaceLabs SL-90202 and SL-90207.

Entities:  

Mesh:

Year:  1995        PMID: 7591026     DOI: 10.1161/01.hyp.26.5.835

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  16 in total

1.  Blood pressure measuring devices: recommendations of the European Society of Hypertension.

Authors:  E O'Brien; B Waeber; G Parati; J Staessen; M G Myers
Journal:  BMJ       Date:  2001-03-03

2.  Masked hypertension and effort-reward imbalance at work among 2369 white-collar workers.

Authors:  P Boucher; M Gilbert-Ouimet; X Trudel; C S Duchaine; A Milot; C Brisson
Journal:  J Hum Hypertens       Date:  2017-06-22       Impact factor: 3.012

3.  Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs.

Authors:  Christopher E Haberman; Chang W Kang; Jefferson D Morgan; Scott A Brown
Journal:  Can J Vet Res       Date:  2006-07       Impact factor: 1.310

Review 4.  Ambulatory blood pressure monitoring: a guide for general practitioners.

Authors:  N Prasad; C Isles
Journal:  BMJ       Date:  1996-12-14

5.  Interactive influences of ethnicity, endothelin-1 gene, and everyday discrimination upon nocturnal ambulatory blood pressure.

Authors:  Mathew J Gregoski; Sarah G Buxbaum; Gaston Kapuku; Yanbin Dong; Haidong Zhu; Mary Davis; Kelsey Gonto; Frank A Treiber
Journal:  Ann Behav Med       Date:  2013-06

6.  Evaluation of a community-based automated blood pressure measuring device.

Authors:  Jacqueline E Lewis; Eleanor Boyle; Lucy Magharious; Martin G Myers
Journal:  CMAJ       Date:  2002-04-30       Impact factor: 8.262

Review 7.  Accuracy of Blood Pressure Measurement Devices in Pregnancy: A Systematic Review of Validation Studies.

Authors:  Natalie A Bello; Jonathan J Woolley; Kirsten Lawrence Cleary; Louise Falzon; Bruce S Alpert; Suzanne Oparil; Gary Cutter; Ronald Wapner; Paul Muntner; Alan T Tita; Daichi Shimbo
Journal:  Hypertension       Date:  2017-12-11       Impact factor: 10.190

Review 8.  Modern approaches to blood pressure measurement.

Authors:  J A Staessen; E T O'Brien; L Thijs; R H Fagard
Journal:  Occup Environ Med       Date:  2000-08       Impact factor: 4.402

9.  Italian society of hypertension guidelines for conventional and automated blood pressure measurement in the office, at home and over 24 hours.

Authors:  Gianfranco Parati; Stefano Omboni; Paolo Palatini; Damiano Rizzoni; Grzegorz Bilo; Mariaconsuelo Valentini; Enrico Agabiti Rosei; Giuseppe Mancia
Journal:  High Blood Press Cardiovasc Prev       Date:  2013-01-22

10.  Association of insulin resistance and nocturnal fall of blood pressure in GH-deficient adults during GH replacement.

Authors:  R Resende de Lima Oliveira Brasil; D Vieira Soares; L Diniz Carneiro Spina; P Marise Lobo; E Maria Carvalho da Silva; V Aleta Mansur; M F Miguens Castelar Pinheiro; F L Conceição; M Vaisman
Journal:  J Endocrinol Invest       Date:  2007-04       Impact factor: 4.256

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.