Literature DB >> 7586254

Development and characterization of a rapid assay for bedside determinations of cardiac troponin T.

M Müller-Bardorff1, H Freitag, T Scheffold, A Remppis, W Kübler, H A Katus.   

Abstract

BACKGROUND: The appearance of cardiac proteins in blood is the most specific and sensitive indicator of acute myocardial cell necrosis. The measurement of cardiac markers, however, is time consuming and requires sophisticated equipment. To facilitate the biochemical detection for acute myocardial cell necrosis, a whole-blood rapid assay device for cardiac troponin T detection was developed that provides a test result within 20 minutes. METHODS AND
RESULTS: Monoclonal antibody M7 is labeled with gold particles, and antibody 1B10 is labeled with biotin. Both antibodies, as well as buffer substances and detergents, are adsorbed onto paper fleeces mounted below an application well. Heparinized blood (160 microL) applied to this well solubilizes the dry chemistry reagents. Blood cells are separated from plasma via a glass-fiber fleece. The immunocomplexes formed are concentrated within the reading zone by binding of the biotin-labeled antibody with streptavidine immobilized to the test device. Troponin T bound to the test device serves as a control. The detection limit of this assay is 0.18 microgram/L with a cross-reactivity with skeletal troponin T of 0.5%. In clinical analyses involving 25 healthy volunteers, 62 patients with chest pain but without myocardial ischemia, 35 patients with acute myocardial infarction, 24 patients with minor myocardial cell damage due to radiofrequency ablation, and 35 patients with unstable angina, the rapid assay was comparable to the troponin T enzyme immunoassay in regard to sensitivity and specificity.
CONCLUSIONS: This newly developed assay allows accurate, rapid, and convenient diagnosis of acute myocardial cell necrosis.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7586254     DOI: 10.1161/01.cir.92.10.2869

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  7 in total

1.  Cardiospecificity of the 3rd generation cardiac troponin T assay during and after a 216 km ultra-endurance marathon run in Death Valley.

Authors:  H J Roth; R M Leithäuser; H Doppelmayr; M Doppelmayr; H Finkernagel; S P von Duvillard; S Korff; H A Katus; Evangelos Giannitsis; R Beneke
Journal:  Clin Res Cardiol       Date:  2007-04-26       Impact factor: 5.460

Review 2.  Recent advances in the management of unstable angina and non-Q-wave myocardial infarction.

Authors:  R P Steeds; K S Channer
Journal:  Br J Clin Pharmacol       Date:  1998-10       Impact factor: 4.335

3.  Cardiac troponin T in unstable angina. Troponin T could be used to identify patients needing early treatment.

Authors:  A S Wierzbicki; T M Reynolds
Journal:  BMJ       Date:  1996-11-23

4.  Diagnosis of acute myocardial infarction: CK-MB versus cTn-T in Indian patients.

Authors:  Sanjiv Gupta; K N Singh; V Bapat; V Mishra; D K Agarwal; P Gupta
Journal:  Indian J Clin Biochem       Date:  2008-03-06

5.  The effects of facilitated primary PCI by guide wire on procedural and clinical outcomes in acute ST-segment elevation myocardial infarction.

Authors:  Volkhard Kurowski; Evangelos Giannitsis; Dirk P Killermann; Uwe K H Wiegand; Ralph Toelg; Hendrik Bonnemeier; Franz Hartmann; Hugo A Katus; Gert Richardt
Journal:  Clin Res Cardiol       Date:  2007-06-04       Impact factor: 5.460

6.  A new scoring system to stratify risk in unstable angina.

Authors:  Alfredo C Piombo; Juan A Gagliardi; Javier Guetta; Juan Fuselli; Simón Salzberg; Enrique Fairman; Carlos Bertolasi
Journal:  BMC Cardiovasc Disord       Date:  2003-08-20       Impact factor: 2.298

7.  Evaluation of a rapid quantitative determination method of PSA concentration with gold immunochromatographic strips.

Authors:  Cheng-Ching Wu; Hung-Yu Lin; Chao-Ping Wang; Li-Fen Lu; Teng-Hung Yu; Wei-Chin Hung; Jer-Yiing Houng; Fu-Mei Chung; Yau-Jiunn Lee; Jin-Jia Hu
Journal:  BMC Urol       Date:  2015-11-03       Impact factor: 2.264

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.