Literature DB >> 7579628

Application of the fast-evaporation sample preparation method for improving quantification of angiotensin II by matrix-assisted laser desorption/ionization.

A J Nicola1, A I Gusev, A Proctor, E K Jackson, D M Hercules.   

Abstract

The fast-evaporation method of sample preparation has been applied for quantitative analysis using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. An instrumental protocol focusing on improvement of shot-to-shot repeatability and compensation for signal degradation has been developed for quantification of angiotensin II using the fast-evaporation technique and an internal standard. The fast-evaporation method was compared to the standard method of sample preparation (using a multicomponent matrix) in the quantitative analysis of angiotensin II, and found to be superior in several respects. Improvement in sample homogeneity using the fast-evaporation method enhanced both point-to-point repeatibility and sample-to-sample reproducibility. The relative standard deviations of the analyte/internal standard ratios (point RSD) were decreased by a factor of three compared to those obtained using the multicomponent matrix method. The average point RSD was found to be ca. 5% for the fast-evaporation technique. Two internal standards were evaluated for quantification of angiotensin II. The better one, 1-SAR-8-Ile angiotensin II, yielded a relative standard deviation of the standard curve slope of ca. 2.2% over two orders of magnitude of concentration (45 nM to 3000 nM), an improvement by a factor of two over the standard preparation method. Renal microdialysate samples, spiked with angiotensin II and the internal standard 1-SAR-8-Ile angiotensin II, were also analyzed using the fast-evaporation technique. The detection limit was calculated to be in the high attomole range (675 amol). Furthermore, the accuracy for a single determination of angiotensin II concentration in these samples was found to be 13.9% with a relative error of 8.19%.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7579628     DOI: 10.1002/rcm.1290091216

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  12 in total

1.  Practical quantitative biomedical applications of MALDI-TOF mass spectrometry.

Authors:  Martin Bucknall; Kim Y C Fung; Mark W Duncan
Journal:  J Am Soc Mass Spectrom       Date:  2002-09       Impact factor: 3.109

Review 2.  Quantitative matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Mark W Duncan; Heinrich Roder; Stephen W Hunsucker
Journal:  Brief Funct Genomic Proteomic       Date:  2008-09

Review 3.  Critical factors determining the quantification capability of matrix-assisted laser desorption/ionization- time-of-flight mass spectrometry.

Authors:  Chia-Chen Wang; Yin-Hung Lai; Yu-Meng Ou; Huan-Tsung Chang; Yi-Sheng Wang
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

4.  Integrated Microfluidic Aptasensor for Mass Spectrometric Detection of Vasopressin in Human Plasma Ultrafiltrate.

Authors:  J Yang; J Zhu; R Pei; J A Oliver; D W Landry; M N Stojanovic; Q Lin
Journal:  Anal Methods       Date:  2016-05-11       Impact factor: 2.896

5.  Quantification of cysteine oxidation in human estrogen receptor by mass spectrometry.

Authors:  Christian Atsriku; Christopher C Benz; Gary K Scott; Bradford W Gibson; Michael A Baldwin
Journal:  Anal Chem       Date:  2007-03-21       Impact factor: 6.986

6.  Immobilized carbon nanotubes as matrix for MALDI-TOF-MS analysis: applications to neutral small carbohydrates.

Authors:  Shi-fang Ren; Li Zhang; Zhi-hong Cheng; Yin-long Guo
Journal:  J Am Soc Mass Spectrom       Date:  2005-03       Impact factor: 3.109

7.  Triacylglycerol profiling of marine microalgae by mass spectrometry.

Authors:  Megan A Danielewicz; Lisa A Anderson; Annaliese K Franz
Journal:  J Lipid Res       Date:  2011-08-11       Impact factor: 5.922

8.  Development of a hydrophilic interaction liquid chromatography coupled with matrix-assisted laser desorption/ionization-mass spectrometric imaging platform for N-glycan relative quantitation using stable-isotope labeled hydrazide reagents.

Authors:  Zhengwei Chen; Xuefei Zhong; Cai Tie; Bingming Chen; Xinxiang Zhang; Lingjun Li
Journal:  Anal Bioanal Chem       Date:  2017-05-25       Impact factor: 4.142

9.  Quantitative analysis of phospholipids using nanostructured laser desorption ionization targets.

Authors:  Simona Colantonio; John T Simpson; Robert J Fisher; Amichai Yavlovich; Julie M Belanger; Anu Puri; Robert Blumenthal
Journal:  Lipids       Date:  2011-02-15       Impact factor: 1.880

Review 10.  Recommendations for quantitative analysis of small molecules by matrix-assisted laser desorption ionization mass spectrometry.

Authors:  Poguang Wang; Roger W Giese
Journal:  J Chromatogr A       Date:  2017-01-18       Impact factor: 4.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.