Literature DB >> 7573917

Detection of cerebral venous desaturation by continuous jugular bulb oximetry following acute neurotrauma.

S B Lewis1, J A Myburgh, P L Reilly.   

Abstract

A prospective observational study was performed to assess the reliability of fibreoptic oximetric catheters and to identify the incidence and causes of jugular bulb oxygen desaturation in patients with acute closed head injury. There were twenty-five patients (30 +/- 16 years) with GCS < or = 8 in this study. Jugular bulb oximetry, mean arterial pressure, intracranial pressure, end-tidal CO2 and pulse oximetry were monitored continuously. Catheter calibration against a laboratory oximeter was performed post insertion and thereafter eight-hourly. Cerebral venous desaturation was defined as a jugular bulb oxygen saturation < 55% of > 10 minutes duration. There was a poor correlation for the first in vivo calibration (r2 = 0.602, P < 0.001, n = 25). Thereafter a close correlation between jugular bulb catheter and oximetry values was demonstrated (r2 = 0.868, P < 0.001, n = 205). Forty-two episodes of jugular bulb oxygen desaturation of 88 minutes mean duration (range 10 to 555) were observed. 83% occurred within 48 hours following injury. Hypocapnia was associated in 45% of episodes; hypoperfusion in 22%; raised ICP in 9% and a combination of the above in 24%. Validation with a laboratory oximeter is essential prior to continuous jugular bulb oximetry. Sustained episodes of cerebral venous desaturation are frequent within the first 48 hours following acute head injury. Factors such as hypocapnia and cerebral hypoperfusion that primarily reduce cerebral blood flow are predominant.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7573917     DOI: 10.1177/0310057X9502300307

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  6 in total

Review 1.  Neurocritical care and traumatic brain injury.

Authors:  R C Tasker
Journal:  Indian J Pediatr       Date:  2001-03       Impact factor: 1.967

2.  Analysis of abnormal jugular bulb oxygen saturation data in patients with severe head injury.

Authors:  C de Deyne; T Vandekerckhove; J Decruyenaere; F Colardyn
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

Review 3.  Near-Infrared Spectroscopy in the Monitoring of Adult Traumatic Brain Injury: A Review.

Authors:  David J Davies; Zhangjie Su; Michael T Clancy; Samuel J E Lucas; Hamid Dehghani; Ann Logan; Antonio Belli
Journal:  J Neurotrauma       Date:  2015-04-17       Impact factor: 5.269

Review 4.  Multimodal brain monitoring in fulminant hepatic failure.

Authors:  Fernando Mendes Paschoal; Ricardo Carvalho Nogueira; Karla De Almeida Lins Ronconi; Marcelo de Lima Oliveira; Manoel Jacobsen Teixeira; Edson Bor-Seng-Shu
Journal:  World J Hepatol       Date:  2016-08-08

Review 5.  Critical care management of severe traumatic brain injury in adults.

Authors:  Samir H Haddad; Yaseen M Arabi
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-02-03       Impact factor: 2.953

Review 6.  Monitoring of brain and systemic oxygenation in neurocritical care patients.

Authors:  Mauro Oddo; Julian Bösel
Journal:  Neurocrit Care       Date:  2014-12       Impact factor: 3.210

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.