[Water permeability of breathing filters].

H Frankenberger1, M Schulze.   

Abstract

Breathing filters or heat and moisture exchangers (HME), which are placed between a tracheal tube and the Y-piece, allow reuse of breathing tubes without changing between operations. During low-flow and minimal-flow anaesthesia, condensed water accumulates in the breathing circuit. An evaluation of the volume of condensed water is given (Fig. 1). It may be possible that water flows onto the filter surface, for example, when the breathing tubes are lifted. The water permeability of such breathing filters and HME was tested. For the experiments, a commercial breathing circuit and ventilator (Dräger Sulla 808 + Ventilog) and patient model (Fig. 2) were used; 12 breathing filters/HMEs of different manufacturers were tested. Only 3 filters were not permeable to the test volume of 20 ml water. The authors suggest the water volume be checked routinely and the breathing tubes be emptied if necessary.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7573907     DOI: 10.1007/s001010050192

Source DB:  PubMed          Journal:  Anaesthesist        ISSN: 0003-2417            Impact factor:   1.041


  3 in total

1.  Infection prevention during anaesthesia ventilation by the use of breathing system filters (BSF): Joint recommendation by German Society of Hospital Hygiene (DGKH) and German Society for Anaesthesiology and Intensive Care (DGAI).

Authors:  Axel Kramer; Rainer Kranabetter; Jörg Rathgeber; Klaus Züchner; Ojan Assadian; Georg Daeschlein; Nils-Olaf Hübner; Edeltrut Dietlein; Martin Exner; Matthias Gründling; Christian Lehmann; Michael Wendt; Bernhard Martin Graf; Dietmar Holst; Lutz Jatzwauk; Birgit Puhlmann; Thomas Welte; Antony R Wilkes
Journal:  GMS Krankenhhyg Interdiszip       Date:  2010-09-21

2.  [HME filter versus patient-related replacement of tubes from the ventilation circuit for anaesthesia: a cost-benefit analysis].

Authors:  R Kranabetter; M Leier; D Kammermeier; U Krodel
Journal:  Anaesthesist       Date:  2006-05       Impact factor: 1.041

3.  [Prevention of infections under anesthetic breathing with breathing filters: concerted recommendations of the Deutsche Gesellschaft für Krankenhaushygiene e.V. (DGKH) and the Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin e.V. (DGAI)].

Authors:  R Kranabetter; A Kramer; J Rathgeber; K Züchner; O Assadian; G Daeschlein; N-O Hübner; E Dietlein; M Exner; M Gründling; C Lehmann; M Wendt; B M Graf; D Holst; L Jatzwauk; B Puhlmann; T Welte; A R Wilkes
Journal:  Anaesthesist       Date:  2010-12       Impact factor: 1.041

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.