Literature DB >> 7572650

Usefulness of heart rate variability in predicting drug efficacy (metoprolol vs diltiazem) in patients with stable angina pectoris.

J Brouwer1, J W Viersma, D J van Veldhuisen, A J Man in 't Veld, P Sijbring, J Haaksma, W A Dijk, K I Lie.   

Abstract

We investigated whether analysis of heart rate (HR) variability may be used to predict the efficacy of drug treatment of myocardial ischemia. In a double-blind, crossover study, 28 patients with stable angina pectoris, proven coronary artery disease, and myocardial ischemia during Holter monitoring received metoprolol controlled-release 200 mg once daily and diltiazem 60 mg 4 times daily. After a placebo run-in phase and after each treatment period, 72-hour Holter recordings were obtained for HR variability and ST-segment analysis. At baseline, the total duration of myocardial ischemia was 11.4 +/- 13.9 minutes (mean +/- SD per 24 hours), and the total number of episodes was 2.2 +/- 2.3. Metoprolol significantly reduced the total duration of ischemia by -8.7 minutes (95% CI -14.5 to -2.8) and the total number of episodes by -1.9 (-2.9 to -0.8) in patients with a low SD of normal-to-normal intervals at baseline (SDNN), using the median value of 50 ms as a cut-off value. In contrast, significant treatment effects were not observed in patients with a high SDNN at baseline. Similar results were obtained using baseline total power or low-frequency power, but not when using baseline heart rate. Diltiazem reduced the total duration of ischemia by -4.9 minutes (-9.7 to -0.1), but not the number of episodes. Moreover, in contrast to metoprolol, efficacy of diltiazem was not related to baseline HR variability. In conclusion, patients with reduced HR variability at baseline responded to treatment with metoprolol.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7572650     DOI: 10.1016/s0002-9149(99)80222-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Heart rate variability effects of an agonist or antagonists of the beta-adrenoceptor assessed with scatterplot and sequence analysis.

Authors:  B Silke; J G Riddell
Journal:  Clin Auton Res       Date:  1998-06       Impact factor: 4.435

2.  Evaluation of the effect on heart rate variability of a beta2-adrenoceptor agonist and antagonist using non-linear scatterplot and sequence methods.

Authors:  C G Hanratty; B Silke; J G Riddell
Journal:  Br J Clin Pharmacol       Date:  1999-02       Impact factor: 4.335

  2 in total