Literature DB >> 7571384

A comparison of simple continuous versus simple interrupted suture patterns for tracheal anastomosis after large-segment tracheal resection in dogs.

R B Fingland1, C I Layton, G A Kennedy, J C Galland.   

Abstract

Two suture techniques for tracheal anastomosis after large-segment tracheal resection were compared. Eight cartilages were resected from the trachea of each of 12 dogs; anastomoses with 4-0 polydioxanone suture were created using a simple continuous suture technique in six dogs and a simple interrupted suture technique in six dogs. Surgical time was shorter but apposition of tracheal segments at the time of surgery was less precise with the simple continuous suture technique. The dogs were evaluated for 150 days after surgery. Clinical abnormalities after tracheal resection and anastomosis were not observed. Percent dorsoventral luminal stenosis was calculated by measuring the tracheal lumen diameter on lateral cervical radiographs. Percent luminal stenosis was calculated planimetrically using a computerized digitizing tablet. Anastomotic stenosis was mild in all dogs; however, the mean percent.luminal stenosis determined planimetrically was significantly greater for dogs that had the simple continuous suture technique. Planimetric measurements of cross-sectional area made before and after formalin fixation were not significantly different. Radiographic determination of percent dorsoventral luminal stenosis was a poor predictor of diminution of cross-sectional area determined planimetrically.

Entities:  

Mesh:

Year:  1995        PMID: 7571384     DOI: 10.1111/j.1532-950x.1995.tb01337.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  5 in total

1.  Long-term outcome of conventional endotracheal tube balloon dilation of tracheal stenosis in a dog.

Authors:  Nili Kahane; Gilad Segev
Journal:  Can Vet J       Date:  2014-01       Impact factor: 1.008

2.  Management of a tracheal intussusception in a dog.

Authors:  Manureva Lebreton; Eric Bomassi; Sebastien Etchepareborde
Journal:  Can Vet J       Date:  2017-07       Impact factor: 1.008

3.  COMPARISON OF FLUOROSCOPY AND COMPUTED TOMOGRAPHY FOR TRACHEAL LUMEN DIAMETER MEASUREMENT AND DETERMINATION OF INTRALUMINAL STENT SIZE IN HEALTHY DOGS.

Authors:  Jackie M Williams; Ingar A Krebs; Elizabeth A Riedesel; Qianqian Zhao
Journal:  Vet Radiol Ultrasound       Date:  2016-01-19       Impact factor: 1.363

4.  Ultrasonographic evaluation of tracheal collapse in dogs.

Authors:  Kidong Eom; Kumjung Moon; Yunsang Seong; Taeho Oh; Sungjoon Yi; Keunwoo Lee; Kwangho Jang
Journal:  J Vet Sci       Date:  2008-12       Impact factor: 1.672

5.  Radiographic vertical tracheal diameter assessment at different levels along the trachea as an alternative method for the evaluation of the tracheal diameter in non-brachycephalic small breed dogs.

Authors:  Ayman A Mostafa; Clifford R Berry
Journal:  BMC Vet Res       Date:  2022-02-01       Impact factor: 2.741

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.