Optimization of signal-to-noise ratio for multilayer PZT transducers.

R L Goldberg1, S W Smith.   

Abstract

In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedance near the resonance frequency. This results in poor signal-to-noise ratio (SNR) of the array elements. It has previously been demonstrated that transducers made from multilayer PZT ceramics have lower electrical impedance and greater SNR than comparable single layer elements. A simplified circuit model has been developed to optimize the SNR for multilayer ceramic (MLC) transducers. In this model, an electronic transmitter excites the array element and in the receive mode, the element drives a coaxial cable load terminated by a high impedance preamplifier. The transducer impedance is Zt/N2, where N is the number of piezoelectric layers. Maximum transmit signal is obtained when N = Ntx such that the transducer impedance, Zt/Ntx2, is matched to the source impedance. Maximum receive signal is obtained when N = Nrx such that the transducer impedance, Zt/Nrx2, is matched to the coaxial cable reactance. For maximum pulse-echo signal, the transducer should be designed with N = square root of Ntx Nrx, the geometric mean of Ntx and Nrx. Using this optimization technique, a 1.5-D array was designed with 3 layers for maximum pulse-echo SNR. Results of simulations from the simplified circuit analysis were consistent with those of the KLM model. The 3 layer array was fabricated as well as a single layer control array. The measured transmit signal and receive signal agreed with the simulation results.

Entities:  

Mesh:

Year:  1995        PMID: 7571210     DOI: 10.1177/016173469501700202

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  3 in total

1.  Coherence-based quantification of acoustic clutter sources in medical ultrasound.

Authors:  James Long; Will Long; Nick Bottenus; Gregg Trahey
Journal:  J Acoust Soc Am       Date:  2020-08       Impact factor: 1.840

Review 2.  Spatial Coherence in Medical Ultrasound: A Review.

Authors:  James Long; Gregg Trahey; Nick Bottenus
Journal:  Ultrasound Med Biol       Date:  2022-03-11       Impact factor: 3.694

3.  Lateral mode coupling to reduce the electrical impedance of small elements required for high power ultrasound therapy phased arrays.

Authors:  Kullervo Hynynen; Jianhua Yin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.