Methods for estimation of subsample time delays of digitized echo signals.

I Céspedes1, Y Huang, J Ophir, S Spratt.   

Abstract

Time delay estimation (TDE) is commonly performed in practice by crosscorrelation of digitized echo signals. Since time delays are generally not integral multiples of the sampling period, the location of the largest sample of the crosscorrelation function (ccf) is an inexact estimator of the location of the peak. Therefore, one must interpolate between the samples of the ccf to improve the estimation precision. Using theory and simulations, we review and compare the performance of several methods for interpolation of the ccf. The maximum likelihood approach to interpolation is the application of a reconstruction filter to the discrete ccf. However, this method can only be approximated in practice and can be computationally intensive. For these reasons, a simple method is widely used that involves fitting a parabola (or other curve) to samples of the ccf in the neighborhood of its peak. We describe and compare two curve-fitting methods: parabolic and cosine interpolation. Curve-fitting interpolation can yield biased time-delay estimates, which may preclude the use of these methods in some applications. The artifactual effect of these bias errors on elasticity imaging by elastography is discussed. We demonstrate that reconstructive interpolation is unbiased. An iterative implementation of the reconstruction procedure is proposed that can reduce the computation time significantly.

Entities:  

Mesh:

Year:  1995        PMID: 7571208     DOI: 10.1177/016173469501700204

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  56 in total

1.  Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring.

Authors:  Elisa E Konofagou; Caroline Maleke; Jonathan Vappou
Journal:  Curr Med Imaging Rev       Date:  2012

2.  Experimental validation of acoustic radiation force induced shear wave interference patterns.

Authors:  Kenneth Hoyt; Zaegyoo Hah; Chris Hazard; Kevin J Parker
Journal:  Phys Med Biol       Date:  2011-11-29       Impact factor: 3.609

3.  Theoretical Analysis of Shear Wave Interference Patterns by Means of Dynamic Acoustic Radiation Forces.

Authors:  Kenneth Hoyt
Journal:  Int J Multiphys       Date:  2011-03-01

4.  Temporal averaging of two-dimensional correlation functions for velocity vector imaging of cardiac blood flow.

Authors:  Hiroki Takahashi; Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2015-03-17       Impact factor: 1.314

5.  A novel performance descriptor for ultrasonic strain imaging: a preliminary study.

Authors:  Jingfeng Jiang; Timothy J Hall; Amy M Sommer
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

6.  Two-dimensional simulations of displacement accumulation incorporating shear strain.

Authors:  Matthew Bayer; Timothy J Hall; Lucio P Neves; A A O Carneiro
Journal:  Ultrason Imaging       Date:  2014-01       Impact factor: 1.578

7.  Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver.

Authors:  Nicholas Rubert; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2014-04       Impact factor: 1.578

8.  An approach to unbiased subsample interpolation for motion tracking.

Authors:  Matthew M McCormick; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

9.  Variance and covariance of accumulated displacement estimates.

Authors:  Matthew Bayer; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

10.  Linear and nonlinear elasticity imaging of soft tissue in vivo: demonstration of feasibility.

Authors:  Assad A Oberai; Nachiket H Gokhale; Sevan Goenezen; Paul E Barbone; Timothy J Hall; Amy M Sommer; Jingfeng Jiang
Journal:  Phys Med Biol       Date:  2009-01-30       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.