Literature DB >> 7567201

Does continuous positive airway pressure (CPAP) during weaning from intermittent mandatory ventilation in very low birth weight infants have risks or benefits? A controlled trial.

J L Tapia1, A Bancalari, A González, M E Mercado.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate three ventilator weaning strategies and to evaluate whether the use of continuous positive airway pressure (CPAP) via a nasopharyngeal or endotracheal tube would increase the likelihood of extubation failure in very low birth weight (VLBW) infants. STUDY
DESIGN: We studied prospectively 87 preterm infants (mean +/- SD; birth weight: 1078 +/- 188 g; gestational age: 28.8 +/- 2.2 weeks) who were in the process of being weaned from intermittent mandatory ventilation (IMV). Infants were assigned by systematic sampling to one of the following three treatment groups: (1) direct extubation from IMV (D.EXT) (n = 30); (2) preextubation endotracheal CPAP (ET-CPAP) for 12-24 hr (n = 28); or (3) postextubation nasopharyngeal CPAP (NP-CPAP) for 12-24 hr (n = 29). Failure was defined as the need for resumption of mechanical ventilation within 72 hr of extubation due to frequent or severe apnea and/or respiratory failure (pH < 7.25, PaCO2 > 60 mm Hg, and/or requirement for oxygen FiO2 > 60%).
RESULTS: There were no significant differences in failure rates among the three procedures. Failures were 2/30 (7%) in D.EXT; 4/28 (14%) in ET-CPAP; and 7/29 (24%) in the NP-CPAP. There were also no differences in FiO2, PaO2, and respiratory rates before and after discontinuation of IMV among the three groups. PaCO2 values were slightly higher in the NP-CPAP group 12-24 hr after weaning from IMV.
CONCLUSION: We were unable to demonstrate a clear difference in extubation outcome by use of CPAP administered via an endotracheal or nasopharyngeal tube when compared to direct extubation from low-rate IMV in VLBW infants.

Entities:  

Mesh:

Year:  1995        PMID: 7567201     DOI: 10.1002/ppul.1950190505

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  9 in total

Review 1.  Continuous distending pressure.

Authors:  C Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-09       Impact factor: 5.747

Review 2.  Weaning from assisted ventilation: art or science?

Authors:  S K Sinha; S M Donn
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-07       Impact factor: 5.747

Review 3.  CPAP review.

Authors:  Olie Chowdhury; Catherine J Wedderburn; Donovan Duffy; Anne Greenough
Journal:  Eur J Pediatr       Date:  2011-12-16       Impact factor: 3.183

4.  Randomised trial of elective continuous positive airway pressure (CPAP) compared with rescue CPAP after extubation.

Authors:  N J Robertson; P A Hamilton
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1998-07       Impact factor: 5.747

Review 5.  Risks and benefits of therapies for apnoea in premature infants.

Authors:  J M Hascoet; I Hamon; M J Boutroy
Journal:  Drug Saf       Date:  2000-11       Impact factor: 5.606

6.  Nasal high frequency ventilation in neonates with moderate respiratory insufficiency.

Authors:  M van der Hoeven; E Brouwer; C E Blanco
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1998-07       Impact factor: 5.747

7.  Randomised, controlled trial of nasal continuous positive airway pressure in the extubation of infants weighing 600 to 1250 g.

Authors:  P Davis; R Jankov; L Doyle; P Henschke
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1998-07       Impact factor: 5.747

8.  Prediction of Extubation readiness in extremely preterm infants by the automated analysis of cardiorespiratory behavior: study protocol.

Authors:  Wissam Shalish; Lara J Kanbar; Smita Rao; Carlos A Robles-Rubio; Lajos Kovacs; Sanjay Chawla; Martin Keszler; Doina Precup; Karen Brown; Robert E Kearney; Guilherme M Sant'Anna
Journal:  BMC Pediatr       Date:  2017-07-17       Impact factor: 2.125

9.  Decreasing incidence of chronic lung disease despite the gradual reduction of postnatal dexamethasone use in very low birth weight infants.

Authors:  Chang Won Choi; Jong Hee Hwang; Jae Won Shim; Sun Young Ko; Eun Kyung Lee; Sung Shin Kim; Yun Sil Chang; Won Soon Park; Son Moon Shin
Journal:  J Korean Med Sci       Date:  2004-08       Impact factor: 2.153

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.