Literature DB >> 7564858

Superior nerve anastomosis using a low-output CO2 laser on fibrin membrane.

M Ochi1, M Osedo, Y Ikuta.   

Abstract

BACKGROUND AND
OBJECTIVE: To date, no procedure of laser-aided nerve anastomosis has yet proved to be consistently superior to suture nerve repair. This study examines a new method for nerve repair using a low output CO2 laser and fibrin membrane to ascertain the efficacy of this method for nerve regeneration in comparison with the suture method. STUDY DESIGN/
MATERIALS AND METHODS: Both sciatic nerves of 42 Wister rats were used. The left sciatic nerves were cut and reconnected using 70 mW of irradiation on fibrin membrane bridging the nerve stumps, whereas the right sciatic nerves were repaired with two stitches of epineuro-fascicular sutures.
RESULTS: No deleterious effect of the irradiation on nerve regeneration was demonstrated at any time after surgery. The number of myelinated axons larger than 5 microns in diameter and the mean diameter of mylinated axons 8 weeks after surgery were significantly larger in the laser group than those in the suture group (P < 0.05).
CONCLUSION: The results suggest this new method may be useful and effective for clinical nerve repair.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7564858     DOI: 10.1002/lsm.1900170108

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  1 in total

1.  Comparison of collagen biomatrix and omentum effectiveness on peripheral nerve regeneration.

Authors:  Berker Cemil; Durukan Ture; Banu Cevirgen; Figen Kaymaz; Memduh Kaymaz
Journal:  Neurosurg Rev       Date:  2009-03-31       Impact factor: 3.042

  1 in total