Literature DB >> 7564446

Tissue oxygenation with graded dissolved oxygen delivery during cardiopulmonary bypass.

W L Holman1, R D Spruell, E R Ferguson, J J Clymer, W V Vicente, C P Murrah, A D Pacifico.   

Abstract

BACKGROUND: Intravascular perfluorochemical emulsions together with a high oxygen tension may increase the delivery of dissolved oxygen to useful levels. The hypothesis of this study is that increasing the dissolved oxygen content of blood with incremental doses of a perfluorochemical emulsion improves tissue oxygenation during cardiopulmonary bypass in a dose-related fashion. METHODS AND
RESULTS: Oxygen utilization was studied in a profoundly anemic canine model of hypothermic cardiopulmonary bypass. Forty-two dogs underwent normovolemic hemodilution to a hematocrit of 15.8% +/- 0.6% (mean +/- standard error of the mean). Cardiopulmonary bypass was begun and resulted in a hematocrit of 9.4% +/- 0.6%. A standard priming solution was used in the control group (n = 12), and the test groups received 1.35 gm perfluorochemical.kg-1 (n = 10 dogs), 2.7 gm perfluorochemical.kg-1 (n = 10 dogs), or 5.4 gm perfluorochemical.kg-1 (n = 10 dogs) through the venous return cannula. Each animal underwent a series of randomized pump flows (0.25, 0.5, 1.0, 1.5, 2.0, and 3.0 L.min-1.m-2) at 32 degrees C. After the randomized flows were completed at 32 degrees C, the temperature was raised to 38 degrees C and cardiopulmonary bypass was discontinued. Mortality from cardiac failure on separation from cardiopulmonary bypass was 42% in the control group and 20% in perfluorochemical-treated groups. The mean perfluorochemical dose was higher in survivors than in nonsurvivors (2.9 +/- 0.4 versus 1.3 +/- 0.5 gm perfluorochemical.kg-1; p < 0.05). No differences in oxygen consumption or transbody lactate gradient were found between groups during cardiopulmonary bypass. Analysis of mixed venous oxygen tension (a surrogate measure for tissue oxygenation) as a function of cardiopulmonary bypass flow normalized to body surface area showed that the control group had significantly lower mixed venous oxygen tension (p < 0.05) than the perfluorochemical emulsion-treated groups. Furthermore, the differences were related to the perfluorochemical emulsion dose. These differences in mixed venous oxygen tension continued after termination of cardiopulmonary bypass. The coronary sinus oxygen tension and cardiac arterial-venous oxygen content differences during and after cardiopulmonary bypass were similar among the control and perfluorochemical emulsion-treated animals. Dissolved oxygen consumption during and after cardiopulmonary bypass was calculated. Dissolved oxygen consumption increased in the perfluorochemical-treated animals in a perfluorochemical dose-related manner and was significantly higher in perfluorochemical-treated animals than in the control animals (p < 0.05).
CONCLUSIONS: Graded increases in mixed venous oxygen tension during cardiopulmonary bypass were observed in response to graded increases in the dissolved oxygen delivery. These data suggest that enhancing oxygenation with perfluorochemical-dissolved oxygen is an effective temporary substitute for the use of hemoglobin-bound oxygen during cardiopulmonary bypass. Perfluorochemical-dissolved oxygen may be particularly beneficial in the setting of multiple hypoxic stresses.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7564446     DOI: 10.1016/S0022-5223(95)70111-7

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  5 in total

1.  The Emulsified PFC Oxycyte® Improved Oxygen Content and Lung Injury Score in a Swine Model of Oleic Acid Lung Injury (OALI).

Authors:  Ashraful Haque; Anke H Scultetus; Francoise Arnaud; Leonora J Dickson; Steve Chun; George McNamee; Charles R Auker; Richard M McCarron; Richard T Mahon
Journal:  Lung       Date:  2016-10-04       Impact factor: 2.584

Review 2.  Phase-change contrast agents for imaging and therapy.

Authors:  Paul S Sheeran; Paul A Dayton
Journal:  Curr Pharm Des       Date:  2012       Impact factor: 3.116

Review 3.  Blood substitutes. Artificial oxygen carriers: perfluorocarbon emulsions.

Authors:  D R Spahn
Journal:  Crit Care       Date:  1999-09-24       Impact factor: 9.097

4.  The effect of isovolemic hemodilution with oxycyte, a perfluorocarbon emulsion, on cerebral blood flow in rats.

Authors:  Zhong-jin Yang; Chrystal D Price; Gerardo Bosco; Micheal Tucci; Nagwa S El-Badri; Devanand Mangar; Enrico M Camporesi
Journal:  PLoS One       Date:  2008-04-23       Impact factor: 3.240

5.  Functional, Metabolic and Morphologic Results of Ex Vivo Donor Lung Perfusion with a Perfluorocarbon-Based Oxygen Carrier Nanoemulsion in a Large Animal Transplantation Model.

Authors:  Ilhan Inci; Stephan Arni; Ilker Iskender; Necati Citak; Josep Monné Rodriguez; Miriam Weisskopf; Isabelle Opitz; Walter Weder; Thomas Frauenfelder; Marie Pierre Krafft; Donat R Spahn
Journal:  Cells       Date:  2020-11-18       Impact factor: 6.600

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.